• EA-PSI 10360-15 2U
  • EA-PSI 10360-15 2U

EA-PSI 10360-15 2U

0-360V adjustable voltage, 0-15A current, and 1500W auto-ranging power in a compact 2U 19" rack chassis. Built-in function generator with sine/triangle/arbitrary/PV/fuel cell modes, touchscreen HMI, analog & digital remote control, master-slave parallel up to 192kW, and full protections (OVP/OCP/OPP/OT). Ideal for solar inverter MPPT testing, battery charging, automotive electronics, and automated test systems.

Cooling
Water Cooled (Optional)
Output Current
0-15A
Output Power
1500W
Output Voltage
0-360V
Type
2U
Characteristic Curve
U/I/P autoranging
External Control
Analogue 0-5V/0-10V, USB, LAN, Modbus TCP, Profibus, DeviceNet, RS232, CAN
Housing
19" rack
Human Interface
Touch panel & Menu
Special Feature
Function Generator
  • EA-PSI 10360-15 2U

Description

30-Second Fit Check

  • Output: 0-360V, 0-15A, 1500W with true autoranging (U/I/P).
  • AC input: 110-127V / 208-240V ±10% (single phase or two-phase), 45-65Hz. On 110V input, output derates to 1200W.
  • Efficiency: ≤94.5% at full load and full output voltage.
  • Regulation: Load regulation CV ≤0.05% FS, line regulation ≤0.01% FS.
  • Ripple: 30mV rms / 300mV pp (CV mode, 300 kHz BW).
  • Protections: Adjustable OVP, OCP, OPP, plus OT, PF, and safety OVP on 60V models.

What It Is + Why It Matters

  • High-precision programmable DC power supply for R&D labs, production test, battery charging, and PV inverter testing.
  • Autoranging output delivers full power across wide voltage/current range – no manual range switching.
  • Built-in function generator with sine, triangle, rectangle, trapezoid, arbitrary (99 points), ramp, DIN 40839, plus PV and fuel cell simulation (EN 50530 compliant).
  • Master-Slave parallel operation – up to 64 units for 192kW total power; genuine current sharing via Share bus and digital MS bus.
  • High stability: temp coefficient CV ≤30ppm/°C after warm-up.
Note: Remote sensing compensates up to 5% of U_Nom. Always use DC terminal covers when hazardous voltages present.

Key Specs (EA-PSI 10360-15 2U)

  • Voltage range: 0-360V (adjustable).
  • Current range: 0-15A (adjustable).
  • Power range: 1500W (autoranging).
  • Internal resistance simulation: 0.8Ω – 1600Ω.
  • Rise/Fall time (CV): ≤20ms (10-90%).
  • Display accuracy: Voltage ≤0.05% FS, Current ≤0.1% FS.
  • Insulation: AC input to DC output 3750Vrms; DC output to case up to ±1000V (negative pole).
  • Cooling: Variable speed fan (front intake, rear exhaust). Optional water cooling available.

Interfaces & Remote Control

  • Standard digital: USB (rear B port) + Ethernet (100M) supporting SCPI and ModBus RTU; USB host (front) for data logging and sequence loading.
  • Built-in analog interface (15-pin D-Sub): 0-5V / 0-10V selectable range for set/readback of U/I/P/R; includes remote on/off, alarm outputs (OT/OVP/OCP/OPP), and CV/CC status.
  • Optional plug-in modules (IF-AB series): CAN, CANopen, RS232, ModBus TCP, Profinet (1P/2P), Profibus, EtherCAT – installable without opening the device.
  • Web server on LAN port for network configuration and manual SCPI commands.
  • Remote sense for voltage drop compensation (max 5% of U_Nom).

Best for / Not for

  • Best for: Solar inverter MPPT testing (PV simulation EN50530), battery charge/discharge profiling, automotive electronics (DIN 40839 engine start curve), automated test equipment (ATE), fuel cell simulation, and production line burn-in.
  • Not for: Applications requiring output above 360V or above 15A per single unit (use master-slave parallel to scale current); fixed single-voltage unregulated supplies.

Selection Checklist + Integration

  • Confirm AC supply: 208-240V recommended for full 1500W; on 110-127V derated to 1200W.
  • DC cable cross-section: For 15A / 5m length, use at least 4mm² (AWG10); refer to manual table for longer runs.
  • Mounting: 19" rack, 2U height, allow >30cm rear clearance for airflow.
  • For master-slave parallel: Connect Share bus (BNC) and MS bus (RJ45 CAT5); configure termination (BIAS/TERM) per manual.
  • For PV simulation: Prepare IU table (4096 points) on USB or use internal EN50530 day trend; connect a solar inverter as load.
  • Firmware: KE/HMI 3.02+ recommended for extended PV functions and SEMI F47 support.

Download