• EA-PSI 11000-10 2U
  • EA-PSI 11000-10 2U

EA-PSI 11000-10 2U

0-1000V adjustable voltage, 0-10A current, and 3000W auto-ranging power in a compact 2U 19" rack chassis. Built-in function generator with sine/triangle/arbitrary/PV/fuel cell modes, touchscreen HMI, analog & digital remote control, master-slave parallel up to 192kW, and full protections (OVP/OCP/OPP/OT). Ideal for high-voltage battery testing, solar inverter MPPT testing, EV component validation, and automated test systems.

Cooling
Water Cooled (Optional)
Output Current
0-10A
Output Power
3000W
Output Voltage
0-1000V
Type
2U
Characteristic Curve
U/I/P autoranging
External Control
Analogue 0-5V/0-10V, USB, LAN, Modbus TCP, Profibus, DeviceNet, RS232, CAN
Housing
19" rack
Human Interface
Touch panel & Menu
Special Feature
Function Generator
  • EA-PSI 11000-10 2U

Description

30-Second Fit Check

  • Output: 0-1000V, 0-10A, 3000W with true autoranging (U/I/P).
  • AC input: 110-127V / 208-240V ±10% (single phase or two-phase), 45-65Hz. On 110V input, output derates to 1500W.
  • Efficiency: ≤95% at full load and full output voltage.
  • Regulation: Load regulation CV ≤0.05% FS, line regulation ≤0.01% FS.
  • Ripple: 100mV rms / 2000mV pp (CV mode, 300 kHz / 20 MHz BW).
  • Protections: Adjustable OVP, OCP, OPP, plus OT, PF.
  • Cooling: Variable speed fan (standard) or optional water cooled for silent operation in clean environments.

What It Is + Why It Matters

  • High-voltage programmable DC power supply for R&D labs, EV battery testing, PV inverter validation, and industrial ATE.
  • Autoranging output delivers full 3000W across wide voltage/current range – no manual range switching.
  • Built-in function generator with sine, triangle, rectangle, trapezoid, arbitrary (99 points), ramp, DIN 40839, plus PV and fuel cell simulation (EN 50530 compliant).
  • Master-Slave parallel operation – up to 64 units for 192kW total power; genuine current sharing via Share bus and digital MS bus.
  • High stability: temp coefficient CV ≤30ppm/°C after warm-up.
Note: Remote sensing compensates up to 5% of U_Nom. Always use DC terminal covers when hazardous voltages present.

Key Specs (EA-PSI 11000-10 2U)

  • Voltage range: 0-1000V (adjustable).
  • Current range: 0-10A (adjustable).
  • Power range: 3000W (autoranging).
  • Internal resistance simulation: 3Ω – 6000Ω.
  • Rise/Fall time (CV): ≤20ms (10-90%).
  • Display accuracy: Voltage ≤0.05% FS, Current ≤0.1% FS.
  • Insulation: AC input to DC output 3750Vrms; DC minus to PE ±1500V, DC plus to PE +2000V.
  • Output capacitance: 60μF.

Interfaces & Remote Control

  • Standard digital: USB (rear B port) + Ethernet (100M) supporting SCPI and ModBus RTU; USB host (front) for data logging and sequence loading.
  • Built-in analog interface (15-pin D-Sub): 0-5V / 0-10V selectable range for set/readback of U/I/P/R; includes remote on/off, alarm outputs (OT/OVP/OCP/OPP), and CV/CC status.
  • Optional plug-in modules (IF-AB series): Profibus, ProfiNet, CAN, CANopen, RS232, ModBus TCP, EtherCAT, DeviceNet – installable without opening the device.
  • Web server on LAN port for network configuration and manual SCPI commands.
  • Remote sense for voltage drop compensation (max 5% of U_Nom).

Best for / Not for

  • Best for: High-voltage battery pack testing (EV, ESS), solar inverter MPPT testing (PV simulation up to 1000V), fuel cell simulation, DC-DC converter validation, capacitor charging, and automotive electronics (DIN 40839).
  • Not for: Applications requiring output above 1000V or above 10A per single unit (use master-slave parallel to scale current); low-voltage high-current applications (consider other PSI 10000 models).

Selection Checklist + Integration

  • Confirm AC supply: 208-240V recommended for full 3000W; on 110-127V derated to 1500W.
  • DC cable cross-section: For 10A / 5m length, use at least 2.5mm² (AWG13) with appropriate insulation rating for 1000V.
  • Mounting: 19" rack, 2U height, allow >30cm rear clearance for airflow. For silent operation, consider optional water cooling.
  • For master-slave parallel: Connect Share bus (BNC) and MS bus (RJ45 CAT5); configure termination (BIAS/TERM) per manual.
  • For high-voltage safety: Always use included DC terminal covers and follow discharge procedure (capacitors may hold charge).
  • For PV simulation: Prepare IU table (4096 points) on USB or use internal EN50530 day trend; connect a solar inverter as load.
  • Firmware: KE/HMI 3.02+ recommended for extended PV functions and SEMI F47 support.

Download

Get in Touch with TPS
Name*
Business Email*
Company Name
Country/Region
Inquiry Type*
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.