• KFS1200T200
  • KFS1200T200

KFS1200T200

High-voltage KFS1200 Series 1200W AC/DC power supply with 200VDC output, 6A rated current, and 190–200V adjustable range in a compact 108.8 × 278.1 × 41mm design. With 90–264VAC universal input, peak power up to 3800W for 5 seconds, intelligent cooling control, and active current sharing, it is ideal for industrial and medical systems, collaborative robots, and linear motor equipment.

Input Voltage Range
Single-phase 90VAC - 264VAC
Input Voltage Frequency
50Hz - 60Hz
Output Voltage
200V
Rated Current
0-6A
Peak Output Current
19A
Rated Power
1200W
Peak Output Power
3800W @ Vin≥220VAC
Output Ripple
≤1%
Peak Efficiency @230Vac
94% (exclude fan power)
Outline
4.28“x10.95”x1.61“ or 108.8mmx278.1mmx41mm
EMC
CLASS B Conducted and CLASS A Radiated Emissions
  • KFS1200T200

Description

30-Second Fit Check

  • Output: 200V DC, 6A (1200W)
  • Trim range: 190–200V (tight window—confirm your exact requirement)
  • Peak current: 19A peak
  • Input: 90–264VAC (47–63Hz)
  • Controls: DC_OK + remote sense + remote on/off; PMBus/CANBus optional

What It Is & Why It Matters

  • High-voltage rail targeting where setpoint accuracy and integration clarity matter
  • DC_OK supports faster fault isolation in service workflows
  • Remote sense helps keep the delivered voltage closer to the target under load
  • Series isolation/leakage specs are explicitly listed—useful for high-voltage risk review

Key Specs (Evidence)

  • 200V / 6A rated output
  • Series peak: 3800W for 5s when input ≥180VAC
  • Isolation (series): primary-secondary 3000VAC; primary-earth 1500VAC; secondary-earth 1500VAC
  • Leakage (series): touch <100µA; earth <500µA
  • Aux: 5V/2A max (series)

Integration & Controls

  • Remote on/off + remote sense compensation
  • DC_OK analog indication signal
  • Optional PMBus/CANBus (confirm ordering)
  • Series lists smart fan speed control—plan airflow and verify in test

Best for / Not for

  • Best for: systems needing a 200V DC rail where the required setpoint fits 190–200V
  • Best for: integration-focused builds that want DC_OK and remote control features
  • Not for: applications requiring a wider trim window than 190–200V
  • Not for: fanless-only installations

Typical Applications & Selection Checklist

  • Applications: industrial/medical AC/DC systems; collaborative robotics subsystems
  • Confirm setpoint fits 190–200V and validate at the load point
  • Validate peak events vs 19A peak and series peak condition
  • Decide whether PMBus/CANBus is required for your program
  • Thermal validation: verify airflow and ambient conditions during end-product testing
RFQ Quick Checklist
  • Quantity + target delivery
  • Required setpoint within 190–200V + steady current
  • Peak events + input voltage condition
  • Need DC_OK / PMBus / CANBus / current sharing (Y/N)
  • Cabinet airflow + altitude
Note: Final compliance/performance depend on end-product design and verification testing. Certifications may vary by model—see datasheet.

Download

Get in Touch with TPS
Name*
Business Email*
Company Name
Country/Region
Inquiry Type*
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.