• KFS1200T48
  • KFS1200T48

KFS1200T48

High-efficiency KFS1200 Series 1200W AC/DC power supply with 48VDC output, 25A rated current, 42–54V adjustable range, and up to 94% efficiency in a compact 108.8 × 278.1 × 41mm enclosure. Featuring 90–264VAC universal input, peak power up to 3800W for 5 seconds, active current sharing, and remote control functions, it is ideal for industrial and medical applications, collaborative robots, and linear motor systems.

Input Voltage Range
Single-phase 90VAC - 264VAC
Input Voltage Frequency
50Hz - 60Hz
Output voltage
48V
Rated Current
0-25A
Peak Output Current
79A
Rated Power
1200W
Peak Output Power
3800W @ Vin≥220VAC
Output Ripple
≤1%
Peak Efficiency @230Vac
94% (exclude fan power)
Outline
4.28“x10.95”x1.61“ or 108.8mmx278.1mmx41mm
EMC
CLASS B Conducted and CLASS A Radiated Emissions
  • KFS1200T48

Description

30-Second Fit Check

  • Output rail: 48V DC systems needing up to 25A (1200W)
  • Peak behavior: up to 79A peak output current (short-duration events)
  • Input: single-phase 90–264VAC global input range (47–63Hz listed)
  • Trim window: output adjustable 42–54V (verify your target setpoint)
  • Controls: DC_OK signal + remote sense + remote on/off (PMBus/CANBus optional)

What It Is & Why It Matters

  • Compact 1200W platform for cabinet or embedded integration where space is limited (dimensions listed in datasheet)
  • Remote sense helps compensate wiring drop so the voltage at the load is closer to your setpoint
  • Active current sharing supports parallel architectures where load distribution is required (verify system design)
  • Smart fan speed control is designed to balance cooling and operating conditions

Key Specs

  • Rated output: 48V, 25A (1200W)
  • Peak power (series): 3800W for 5s when input voltage is ≥180VAC
  • Efficiency (series note): up to 94% max listed on the 48V model (excluding fan loss)
  • Output quality (series): ripple 1% p‑p; dynamic response <5%; regulation <3%
  • Aux rail (series): 5V / 2A max

Only use the trim range and peak window if your end load and test plan confirm stability.

Integration & Controls

  • Signals: DC_OK
  • Control: remote on/off control; remote voltage sense compensation
  • Comms: PMBus or CANBus options (confirm ordering)
  • Altitude: operation up to 5000m is listed for the series

Best For / Not For

  • Best for: 48V DC rails that need a compact 1200W module with a wide 42–54V adjustment window
  • Best for: designs that benefit from DC_OK monitoring and remote sense at the load
  • Not for: applications requiring fanless cooling (this series lists fan speed control)
  • Not for: mains below 90VAC, or peak operation when input is below the datasheet peak condition

Typical Applications & Selection Checklist

  • Applications (listed/implied): industrial/medical AC/DC power systems; collaborative robotics power subsystems
  • Setpoint check: confirm your required voltage fits 42–54V
  • Peak check: validate peak duration vs your load event and the 5s peak condition
  • Integration check: decide if you need DC_OK to PLC/HMI, and whether PMBus/CANBus is required
  • Thermal check: design airflow around the module and validate cabinet temperature in test
RFQ Quick Checklist
  • Quantity + target delivery date
  • Required setpoint within 42–54V + continuous current
  • Peak event description (duration + frequency)
  • Need current sharing (Y/N); need PMBus/CANBus (Y/N)
  • Installation limits: airflow, ambient temperature, altitude
Note: Final compliance and real-world performance depend on end-product design, installation, and verification testing. Certifications may vary by model—see datasheet.

Download

Get in Touch with TPS
Name*
Business Email*
Company Name
Country/Region
Inquiry Type*
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.