• KFS1200T85
  • KFS1200T85

KFS1200T85

Compact KFS1200 Series 1200W AC/DC power supply with 85VDC output, 14.2A rated current, and 80–90V adjustable range in a 108.8 × 278.1 × 41mm enclosure. Featuring 90–264VAC universal input, peak power up to 3800W for 5 seconds, intelligent fan speed control, and active current sharing, it is suitable for industrial and medical applications, collaborative robots, and linear motor systems.

Input Voltage Range
Single-phase 90VAC - 264VAC
Input Voltage Frequency
50Hz - 60Hz
Output Voltage
85V
Rated Current
0-14.2A
Peak Output Current
44.7A
Rated Power
1200W
Peak Output Power
3800W @ Vin≥220VAC
Output Ripple
≤1%
Peak Efficiency @230Vac
94% (exclude fan power)
Outline
4.28“x10.95”x1.61“ or 108.8mmx278.1mmx41mm
EMC
CLASS B Conducted and CLASS A Radiated Emissions
  • KFS1200T85

Description

30-Second Fit Check

  • Output: 85V DC, 14.2A (1200W)
  • Trim range: 80–90V
  • Peak current: 44.7A peak
  • Input: 90–264VAC global input range (47–63Hz listed)
  • Controls: DC_OK + remote sense + remote on/off; PMBus/CANBus optional

What It Is & Why It Matters

  • 85V rail support with an 80–90V trim window for setpoint alignment
  • Remote sense helps keep the delivered voltage closer to target under load
  • Active current sharing supports load distribution in parallel architectures
  • Series lists 5000m altitude operation for high-elevation installations

Key Specs (Evidence)

  • 85V / 14.2A rated output
  • Series peak power: 3800W for 5s when input ≥180VAC
  • Output quality (series): ripple 1% p‑p; dynamic response <5%; regulation <3%
  • Aux: 5V/2A max (series)
  • Smart fan speed control (series)

Integration & Controls

  • DC_OK analog indication signal
  • Remote on/off + remote sense compensation
  • PMBus/CANBus optional (confirm ordering)
  • Plan airflow and verify thermal conditions during system testing

Best for / Not for

  • Best for: equipment built around an 85V rail that needs a trim window (80–90V)
  • Best for: designs that benefit from DC_OK monitoring and remote sense
  • Not for: fanless-only requirements
  • Not for: operation below 90VAC input

Typical Applications & Selection Checklist

  • Applications: industrial/medical AC/DC systems; collaborative robotics subsystems
  • Confirm your setpoint fits 80–90V
  • Validate peak events vs 44.7A peak current and the series peak condition
  • Decide whether current sharing is required for your architecture
  • Verify installation airflow and ambient during verification testing
RFQ Quick Checklist
  • Quantity + target delivery
  • Target voltage within 80–90V + steady-state current
  • Peak events + input voltage condition
  • Need current sharing / PMBus / CANBus (Y/N)
  • Altitude + thermal environment
Note: Final compliance and performance depend on end-product design and verification testing. Certifications may vary by model—see datasheet.

Download

Get in Touch with TPS
Name*
Business Email*
Company Name
Country/Region
Inquiry Type*
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.