Decision summary: The CP1000 Series is a compact 1,000W AC/DC lithium battery charger platform for LFP and NCM packs used in AGV/AMR charging, autonomous cleaning equipment, medical carts, and embedded industrial systems. Select it by chemistry, cell count, full-charge voltage, allowable charge current, and system controls - not by the voltage label alone.
Where a CP1000 1kW Battery Charger Fits
The CP1000 Series addresses a common OEM decision: how to integrate a compact, globally deployable charger into equipment that carries an onboard lithium battery. Its single-phase 90-264Vac input, built-in LFP and NCM charge curves, CAN communication, remote ON/OFF, remote voltage sense compensation, and 12V/1A auxiliary output make it a practical candidate when the charger is part of a larger machine rather than a stand-alone consumer accessory.
The series spans seven voltage platforms through the CP1000T24, CP1000T28, CP1000T36, CP1000T48, CP1000T60, CP1000T72, and CP1000T100. All are rated at 1,000W, while maximum output current decreases as the platform voltage rises. That breadth can help an OEM standardize controls, mechanical planning, and supplier coordination across several equipment variants.
CP1000 is strongest when the battery pack matches one of the defined profiles and the system team wants predictable charging behavior. It is not the right starting point when the project requires an unrestricted, field-programmable charging algorithm. TPS can review the pack data, identify a suitable CP1000 configuration, or propose an equivalent or customized charging solution when the standard profile does not fit.
Best-Fit Industrial Applications
1. AGV and AMR Charging Modules
Warehouse vehicles and autonomous mobile robots need repeatable charging at a docking station, clear coordination with the BMS, and protection against service errors. CP1000's automatic battery connection detection, reverse-polarity detection, charge-complete stop, CAN interface, and remote ON/OFF can support a controlled docking sequence. The integrator still needs to define contactor logic, precharge behavior if required, connector current rating, pack wake-up logic, and fault recovery. For a 48V-class fleet, for example, compare the pack's actual full-charge voltage against the profiles on the CP1000T48 product page before using the platform label as the selection criterion.
2. Autonomous Cleaning and Service Robots
Cleaning robots often combine a tight equipment envelope with long operating hours and unattended charging. The CP1000 enclosure is approximately 127.3 x 215.6 x 43mm, allowing it to fit in a dock, service bay, or protected machine compartment. Smart fan speed control helps manage cooling demand, but system designers must preserve the airflow path and account for dust, filters, acoustic limits, and service intervals. If available charge time is short or battery capacity is large, compare the 1kW platform with the higher-power alternative described in the CP1500 industrial applications guide.
3. Medical Carts and Battery-Powered Clinical Equipment
Mobile diagnostic carts, monitors, and treatment support equipment may require low leakage current, reinforced isolation planning, and controlled charging within a compact assembly. The CP1000 datasheet states 2 x MOPP isolation, contact leakage current below 100 microamps, earth leakage current below 300 microamps, and IEC/UL 60601-1 related safety coverage. These are useful supplier-screening inputs, not an automatic approval of the completed medical system. The OEM should confirm the certificate scope and revisions, applied parts, grounding, accessible surfaces, enclosure, cables, EMC immunity, and risk management for the final product. TPS can support this documentation review and project-level testing strategy; see the related guide to powering medical racks and carts.
4. Industrial OEM Equipment and Mobile Subsystems
Industrial inspection platforms, mobile instruments, linear-motion equipment, and battery-backed machine subsystems can use CP1000 when they require a compact embedded charger and broad AC mains compatibility. Remote sense can help compensate for wiring drop between the charger and battery, while the 12V/1A auxiliary output can supply local controls. Confirm that auxiliary power availability and behavior during startup, faults, and remote shutdown match the control architecture. For nonstandard voltage, communications, mechanics, or harness requirements, TPS can provide project selection, integration engineering, and custom power module support for OEM systems.
CP1000 Model Selection Logic
Step 1 - Identify chemistry and series count. State whether the pack uses LFP or NCM cells and provide the number of cells in series. Do not submit only a marketing voltage such as "48V battery." Different chemistries and series counts can share that label but require different full-charge limits.
Step 2 - Confirm full-charge voltage and BMS limits. Compare the pack manufacturer's charge voltage with the CP1000 FC value. Confirm maximum continuous charge current, temperature-dependent current limits, low-temperature lockout, and the BMS response to charger connection. The charger rating is a ceiling; the pack may require less current.
Step 3 - Check the charging window. A 1,000W source does not guarantee 1,000W into the battery throughout the cycle. Estimate charge time from usable energy divided by accepted charge power, then add margin for the constant-voltage taper, BMS limits, temperature, cable loss, and operational availability. If the required turnaround cannot be met, evaluate a higher-power charger or parallel charging architecture only after the battery supplier approves it.
Step 4 - Define interfaces and installation. Specify CAN protocol expectations, remote ON/OFF logic, remote sense wiring, auxiliary-load requirements, AC connector and protective device, DC connector, harness length, airflow direction, and enclosure conditions. A model that matches voltage but not the integration interface is not RFQ-ready.
CP1000 Voltage Platform Comparison
| Product page | Max current | LFP profile | NCM profile | Selection note |
|---|---|---|---|---|
| CP1000T24 | 41.7A | 7S, FC 25.2V | 6S, FC 25.2V | Highest current; prioritize cable and connector sizing. |
| CP1000T28 | 35.7A | 8S, FC 28.8V | 7S, FC 29.4V | Verify the chemistry-specific voltage limit. |
| CP1000T36 | 27.8A | 11S/12S, FC 40.2/43.8V | 10S/11S, FC 42.0/46.2V | Two profile variants require exact pack data. |
| CP1000T48 | 20.8A | 15S/16S, FC 54.8/58.4V | 13S/14S, FC 54.6/58.8V | Common mobile-equipment range; do not assume one universal 48V profile. |
| CP1000T60 | 16.7A | 20S, FC 72.0V | 17S, FC 71.4V | Suitable only when the pack accepts the defined profile. |
| CP1000T72 | 13.9A | 24S, FC 87.6V | 20S, FC 84.0V | Confirm insulation, connectors, and service procedures. |
| CP1000T100 | 10A | 32S, FC 115.2V | 27S, FC 113.4V | Highest voltage platform; verify DC safety architecture. |
Integration and Installation Considerations
- AC input: The stated rated input is 100-240Vac, with a 90-264Vac operating range and 47-63Hz frequency range. Specify upstream branch protection, disconnecting means, grounding, inrush coordination, connector type, and regional cord or terminal requirements.
- DC wiring: Size conductors, connectors, fuses, contactors, and PCB paths for the model's maximum current, expected ambient temperature, bundling, and duty cycle. Higher-current 24V and 28V platforms demand particular attention to voltage drop and contact heating.
- Remote sense: Route sense leads separately from high-current conductors where practical, protect them against open-circuit or miswiring conditions, and define the point of regulation. Remote sense can compensate cable drop but cannot correct an undersized harness.
- Controls: Include the requested CAN documentation, message set, baud rate, connector pinout, remote ON/OFF polarity, fault behavior, and startup timing in the technical review. Do not assume that "CAN supported" means compatibility with an existing proprietary BMS protocol.
- Thermal design: The product uses intelligent fan control. Preserve inlet and outlet clearance, account for neighboring heat sources, and validate temperature rise in the actual enclosure. Ask TPS for derating and environmental data applicable to the proposed mounting orientation and ambient conditions.
- Mechanical access: Plan around the stated 127.3 x 215.6 x 43mm envelope, plus connectors, harness bend radius, airflow, fasteners, and replacement access. Confirm the production drawing because marketing dimensions may be rounded.
Teams developing a multi-channel or rack-based charging system should also review the battery system power and safety architecture guide. It helps translate a charger specification into channel protection, isolation, emergency shutdown, labeling, and service boundaries.
Safety, EMC, and Reliability: What to Verify
The supplied CP1000 information states IEC/UL 62368-1 plus CAN/CSA 62368-1, IEC/UL 60601-1 plus CAN/CSA 60601-1, Class B conducted and radiated emissions, IEC 60601-1-2 fourth-edition alignment, 2 x MOPP isolation, and MTBF above 500,000 hours. Dielectric withstand values are listed as 4,000Vac primary-to-secondary, 1,500Vac primary-to-earth, and 1,500Vac secondary-to-earth.
For supplier qualification, request the actual certificates and test reports, certification body, model coverage, suffix coverage, standard edition and amendments, issue date, factory information, and any conditions of acceptability. Also ask how the stated MTBF was calculated and under which temperature and load assumptions. This evidence is more useful than a logo alone.
Module-level compliance does not replace final-equipment evaluation. Cable routing, enclosure apertures, grounding, external protection, battery behavior, control firmware, and nearby converters can change emissions, immunity, leakage current, temperature, and fault performance. TPS can combine product selection with engineering review and testing support. For practical planning, use the battery charger EMC and safety testing guide to define evidence needed before design freeze.
Decision Criteria by Stakeholder
| Role | Primary decision | Evidence to request |
|---|---|---|
| Business owner / product manager | Platform reuse, launch risk, service model, and global deployment. | Variant roadmap, delivery plan, customization scope, lifecycle support. |
| Electrical engineer | Pack profile, current, wiring, controls, safety, EMC, and thermal fit. | Datasheet, curves, drawings, pinout, CAN specification, reports, derating data. |
| System integrator / panel builder | Mounting, protection, airflow, interlocks, harnessing, and commissioning. | Mechanical model, installation limits, fault logic, service procedure. |
| Procurement | Exact part number, approved configuration, quantity, lead time, and change control. | Formal quote, MOQ, sample plan, warranty, compliance package, PCN process. |
What to Put in a CP1000 RFQ
Send TPS the following information to turn a general inquiry into a model-confirmation and quotation workflow:
- Battery chemistry, cell manufacturer if relevant, series/parallel configuration, nominal voltage, and exact full-charge voltage.
- Pack capacity in Ah or kWh, BMS maximum charge current, temperature limits, target charge time, and daily duty cycle.
- Preferred platform or candidate page: 24V, 28V, 36V, 48V, 60V, 72V, or 100V.
- AC market and site voltage, protective device plan, grounding method, DC harness length, connector, and remote-sense requirement.
- CAN protocol needs, remote ON/OFF logic, auxiliary-power load, interlocks, indicators, and fault-handling expectations.
- Available space, mounting orientation, airflow, ambient range, altitude, contamination, enclosure rating, and service access.
- Required certificates and reports, destination markets, sample quantity, production forecast, target approval date, and delivery schedule.
TPS ELECTRIC LLC supports global B2B customers with charger selection, equivalent solutions, customization, integration consultation, compliance planning, and project coordination. Share your battery and system requirements so the sales and engineering teams can confirm fit before you lock the design.
Review a CP1000 Product PageRequest Model Confirmation and Quote
Frequently Asked Questions
Can I select a CP1000 model from the battery's nominal voltage?
No. Use chemistry, cells in series, exact full-charge voltage, and allowable charge current. A "48V" LFP pack and a "48V" NCM pack can require different charging limits, and the CP1000T36 and CP1000T48 platforms each include more than one profile variant.
How should we estimate charging time?
Divide the energy to be replenished by the pack's accepted charging power, then add margin for constant-voltage taper, BMS current limits, low or high temperature, cable loss, and charger availability. Validate the result on the real battery rather than assuming 1,000W throughout the cycle.
Does CAN support guarantee compatibility with our BMS?
No. CAN describes the physical communications capability, not a universal application protocol. Include the BMS message set, baud rate, connector pinout, required commands, heartbeat behavior, and fault states in the RFQ so TPS can confirm compatibility or customization needs.
Does a CP1000 charger make the final medical device compliant?
No. The stated charger-level safety, isolation, leakage, and EMC attributes support component evaluation, but the completed device must still be assessed in its actual enclosure, wiring, grounding, control, battery, and use environment. Request current compliance documents and confirm their scope.
What if our pack or interface does not match a standard CP1000 profile?
Send TPS the battery profile, BMS interface, mechanical constraints, forecast quantity, destination markets, and schedule. TPS can evaluate a standard configuration, an equivalent charger solution, or project-specific customization and integration support.
