The EA-PS 9080-50 1U is a 1500 W programmable DC power supply with 0–80 V and 0–50 A ranges in a 19-inch rack enclosure. For automated test equipment, production fixtures, and engineering validation, its value is the combination of an adjustable power envelope, remote interfaces, and a 44 mm enclosure height.
Buying decisions depend on the complete installation: actual test points, AC mains, measurement requirements, rack wiring, and delivery scope. TPS ELECTRIC LLC supports global B2B customers with this class of programmable power products, project selection, and integration consultation. Start with the EA-PS 9080-50 1U product and quotation page, then send the operating conditions that your system must meet.
First decision: 80 V and 50 A are separate maximum ratings. The output is also limited by available power; 80 V at 50 A would require 4000 W and is outside this model’s capability.
Table of Contents
This 80 V, 50 A DC source is a candidate for powering DC/DC converters, industrial electronic assemblies, and fixtures requiring several voltage settings. Its autoranging output can cover multiple operating points without selecting a separate fixed-output supply for each fixture. System integrators should compare the test matrix against both current and power limits.
Panel builders need enclosure depth, cable access, grounding, and cooling information. Electrical engineers need regulation, ripple, and control behavior. Procurement needs a confirmed configuration, documentation package, commercial terms, and delivery plan. Business owners and product managers should assess whether one qualified configuration can serve multiple fixtures and simplify maintenance.
Define pass/fail requirements before requesting supplier comparisons. A useful evaluation separates required performance from desirable features: minimum current at each voltage, allowable ripple at the DUT, control compatibility, and the evidence needed for release. Ask each supplier to identify deviations explicitly. This gives procurement a comparable technical basis and helps engineering avoid approving a unit that meets the headline ratings but misses a critical operating point or installation constraint.
If requirements extend beyond this model, TPS can review related products or an equivalent solution against the same acceptance criteria. The 1500 W and 3000 W 1U selection guide provides family context without replacing model-level verification.
| Parameter | Published value |
|---|---|
| DC ranges | 0–80 V, 0–50 A; up to 1500 W, subject to power limits |
| AC input | 100–264 VAC, 45–65 Hz; active PFC, PF 0.99 |
| Low-input derating | Below 150 VAC: maximum DC output power 1000 W |
| Efficiency | Up to 91% for this model |
| Voltage ripple | 100 mV peak-to-peak / 5.2 mV RMS maximum, at specified bandwidths |
| Current ripple | 4 mA RMS maximum |
| Programming resolution | Typical: 3 mV voltage; 2 mA current, excluding device error |
| Enclosure / weight | 19-inch × 1U × 500 mm; approximately 10.5 kg |
Voltage accuracy is specified below 0.1% of rated value, and current accuracy below 0.2% of rated value. For this model, those percentages correspond to below 80 mV and below 100 mA respectively. Resolution describes the programming increment, not measurement accuracy. Low-current acceptance tests may require an external calibrated instrument.
For positive output voltages, a useful first-pass calculation is Imax = min(50 A, Pavail / Vout), with voltage limited to 80 V. Available power is the lower of the selected power setting and the applicable mains-dependent output limit. Leave margin for test variation and cable losses.
| Test voltage | 1500 W available | 1000 W available |
|---|---|---|
| 24 V | 50 A; current-limited | 41.67 A; power-limited |
| 48 V | 31.25 A | 20.83 A |
| 80 V | 18.75 A | 12.5 A |
A 48 V, 30 A test requires 1440 W before wiring losses. It fits within the nominal 1500 W envelope but leaves only 60 W of headroom. A 48 V, 40 A test requires 1920 W and needs a different power configuration. Submit both continuous and startup conditions to TPS before approving a purchase.
US 120 VAC installations fall into the catalog’s 1000 W output class. An appropriately designed 208 or 230 VAC installation can support the full nominal power, subject to input limits. Active PFC improves input behavior but does not remove the requirement to verify branch-circuit capacity, plugs, and cable ratings.
For converter validation, list input-voltage sweeps, current demand, startup behavior, and fault tests. For production burn-in, specify simultaneous DUT count, fixture voltage drop, operating duration, and ambient temperature. For automation electronics, decide whether repeatable programmable stimulation is needed or a fixed-output supply would be sufficient.
Battery work needs a separate assessment of charge limits, reverse current, isolation, and fault protection. This catalog documents a DC source; it does not establish regenerative sinking or bidirectional operation. If the DUT returns energy, TPS can assess an appropriate load, protective arrangement, or alternative architecture. The electronic DC load selection guide explains requirements on the sinking side.
The standard enclosure is approximately 44 mm high and 500 mm deep. Published enclosure dimensions exclude overall connection clearance. Allocate additional space for rear terminals, cable bend radius, interface plugs, covers, and maintenance access; a cabinet with exactly 500 mm usable depth is not automatically suitable.
Use rack support appropriate for approximately 10.5 kg, and verify mounting provisions with the installation manual. Temperature-controlled fans require an unobstructed cooling path. The catalog specifies 0–50°C operation, humidity below 80% without condensation, and altitude below 2000 m. Evaluate temperature inside the populated rack rather than relying on room temperature.
At 50 A, a hypothetical 10 milliohm total cable-and-contact resistance produces 0.5 V drop and 25 W loss. Size conductors, terminals, protection, and strain relief for actual current and duty. Remote sensing can help regulate voltage at the DUT, but it cannot remove resistive heating or replace adequate conductors.
Route and terminate sense leads according to the model manual, including compensation limits and behavior if a lead opens. The Share Bus supports parallel operation, but the catalog explicitly lists no master-slave function. Confirm compatible units, load sharing, coordinated control, protection, and wiring before treating a parallel assembly as a single source.
Standard remote interfaces include galvanically isolated USB, Ethernet, and a 15-pin female D-Sub analog connection. Analog inputs program voltage, current, and power through selectable 0–5 V or 0–10 V signals. Analog outputs monitor voltage and current; status signals support system supervision.
The catalog specifies SCPI commands and ModBus RTU support for digital control. Obtain the programming manual to confirm transport framing, network configuration, commands, and software compatibility. Specify startup state, communication-loss behavior, readback requirements, and alarm handling. TPS can support interface selection and integration scoping, including custom fixture or control requirements subject to technical review.
Published voltage rise time is a maximum of 15 ms for 10–90% in CV mode; the stated 10–100% load regulation response is below 2.2 ms. These figures do not establish command latency or arbitrary waveform capability. Include a representative DUT and sequence in acceptance testing.
Commission the rack in stages: first verify grounding and wiring, then check local operation with conservative limits, and finally enable remote commands. Record voltage at the DUT alongside supply readback during load changes. Test output disable, protective trips, and recovery after a control interruption. For repeated production stations, retain the approved wiring diagram, interface settings, and test script as part of the configuration record. This makes subsequent units easier to qualify and gives TPS concrete information when supporting an integration issue.
Documented protections include overvoltage, overcurrent, overpower, overtemperature, and power-fail status. Configurable OVP, OCP, and OPP thresholds shut off the DC output and report alarms when triggered. Set thresholds around the DUT’s allowable conditions, then verify their behavior with the intended fixture and control software.
The supplied catalog lists EN 60950, EN 61326, and EN 55022 Class B, plus protection class I, pollution degree 2, and overvoltage category II. It also specifies 2500 VDC insulation from AC input to enclosure and from AC input to DC output. These are published technical statements, not proof of every destination-market approval.
Request declarations and relevant test evidence for the exact supplied model and revision. If a US project requires UL listing or another specific approval, make that requirement explicit; the attachment does not establish it. TPS can discuss EMC and safety evaluation support, while equipment-level acceptance depends on the finished installation and required evidence.
The catalog’s automatic output-discharge feature is stated for models rated 200 V and above, so do not assign it to this 80 V unit. Likewise, verify any requested internal-resistance simulation separately because the supplied specification does not document that function.
Use the model-specific TPS inquiry page to request technical confirmation and a formal quote. Provide a concise operating-point table instead of only requesting an “80 V, 50 A power supply.” That distinction helps TPS identify a suitable product or assess an equivalent solution without assuming incompatible maximum ratings.
Ask the quotation to confirm the supplied configuration, included accessories and software, current availability, lead time, warranty terms, shipping scope, and applicable commercial conditions. Those details are project-specific; the supplied technical catalog does not establish stock or delivery commitments.
TPS supports global B2B sourcing and solution consultation for programmable DC power projects. For custom rack wiring, fixtures, coordinated control, or broader integration, provide drawings and acceptance requirements so the engineering scope can be assessed. If sustained demand exceeds 1500 W, use the higher-power rack supply selection guide to frame the alternative discussion.
Move from ratings to a confirmed project configuration. Send TPS your test points, mains voltage, rack constraints, and delivery requirements for product selection and integration consultation.
Request an EA-PS 9080-50 1U QuoteNo. That operating point requires 4000 W. At the full 1500 W power limit, calculated current at 80 V is 18.75 A; 50 A is available only at voltages up to 30 V, subject to operating conditions.
No. The supplied catalog limits output to 1000 W below 150 VAC. Confirm site mains and branch-circuit suitability before sizing the test. At 48 V, 1000 W permits approximately 20.83 A before installation margin.
The catalog lists isolated USB, Ethernet, and selectable 0–5 V or 0–10 V analog control. SCPI and ModBus RTU are documented; confirm protocol implementation and software compatibility against the current programming manual.
The catalog supports parallel operation through Share Bus or analog control and states that master-slave operation is unavailable. Ask TPS to review unit compatibility, current sharing, protection, and coordinated control for your proposed arrangement.
Send voltage/current operating points, AC supply, installation constraints, interface choice, required compliance evidence, quantity, destination, and timing. TPS can assess the model, review alternatives, and scope integration or customization support for the project.
EA-PUB 10000 4U Series: 30 kW Bidirectional DC Power for Scalable Test Systems
EA-EL 9000 B Series: Programmable DC Loads for Industrial Test Systems
TBM800-53KTIT Industrial Applications: 53 kW Bidirectional Power for Battery Test and Regenerative Aging
YB-D Series Compliance & Testing: Qualify EMI Filters for Industrial Control Panels
EA-PS3000 C Series Power Design Guide: Select and Integrate a DC Test Bench Supply
EA-PS 10060-120 2U: 60 V, 120 A, 3 kW Programmable DC Power Supply
EA-PS 9080-50 1U: 1500 W Programmable DC Power for Test Racks
eTM-605, eTM-605F and eTM-605P Compliance Guide: Qualify 60V Bench Power Supplies for Lab and Production Testing