EA-PS 10060-120 2U: 60 V, 120 A, 3 kW Programmable DC Power Supply

By Lily November 16th, 2026 38 views
Evaluate the EA-PS 10060-120 2U programmable DC power supply, offering 0–60V and 0–120A ranges within a 3kW power envelope. Review AC input derating, control interfaces and rack integration. Contact TPS ELECTRIC LLC for model selection, engineering consultation and project quotations.
EA-PS 10060-120 2U: 60 V, 120 A, 3 kW Programmable DC Power Supply,TPS ELECTRIC LLC

TPS ELECTRIC LLC · PRODUCT SELECTION

The EA-PS 10060-120 2U is a programmable DC power supply for teams that need up to 60 V, up to 120 A and a 3 kW sourcing envelope in a 19-inch rack. Its value depends on matching the actual load profile, facility power and integration requirements before purchase.

For system integrators, panel builders, procurement teams and electrical engineers, TPS ELECTRIC LLC supports selection of this product class, equivalent solutions and project integration. Start with the EA-PS 10060-120 2U product and quotation page and use the checks below to define a technically complete request.

EA-PS 10060-120 2U limits: 60 V, 120 A and 3 kW; 1.5 kW on low-line AC input.

Model limits apply simultaneously; the current available at any voltage also depends on the power limit.

Model Specifications That Matter Before Ordering

This 60 V programmable DC power supply combines constant-voltage, constant-current and constant-power regulation with adjustable internal-resistance operation. A 5-inch color touchscreen supports local setup, while remote interfaces support automated test equipment. The following values come from the supplied series manual and its model-specific table.

Selection item EA-PS 10060-120 2U
DC output limits 0–60 V; 0–120 A; 0–3000 W
AC input 110–127 VAC or 208–240 VAC, each ±10%; 45–65 Hz
Low-line DC power 1500 W on the 110–127 VAC nominal range
CV ripple 10 mV RMS at 300 kHz bandwidth; 100 mV peak-to-peak at 20 MHz bandwidth
Load regulation CV ≤0.05% full scale; CC ≤0.1% full scale
Remote sense Up to 5% of nominal voltage: 3 V for this model, in CV operation
Internal-resistance setting 0.02–24 ohms
Built-in control USB, 100 Mbit Ethernet and isolated 15-pin analog interface
Mechanical format 19-inch, 2U; approximately 12.7 kg / 28 lb

Full scale is the instrument’s nominal range, rather than the selected operating value. Consequently, regulation figures should not be read as percentages of a small setpoint. Specifications carrying tolerances apply under the manual’s stated conditions, including warm-up and reference temperature. Procurement should confirm the current hardware revision and documentation with TPS.

For a broader voltage or current comparison, the 2U series selection guide provides useful context. Select this particular model when its complete operating envelope covers your device under test, or DUT, with practical margin.

Calculated output envelopes for 3000 W and 1500 W operation, limited to 60 V and 120 A.

Calculated selection envelope: I ≤ min(120 A, available power ÷ voltage), with voltage limited to 60 V.

Check the Power Envelope Against Your Application

A 60 V, 120 A specification does not mean 7200 W is available. With a full-power AC connection, the supply can deliver 120 A up to 25 V; above that point, available current follows the 3 kW power ceiling. These calculated examples illustrate the selection boundary:

Required operating point Power Assessment at full AC input
24 V at 100 A 2400 W Within nominal limits
25 V at 120 A 3000 W At the rated boundary
48 V at 50 A 2400 W Within nominal limits
48 V at 62.5 A 3000 W At the rated boundary
60 V at 50 A 3000 W At the rated boundary
48 V at 100 A 4800 W Requires another configuration

Boundary values leave no allowance for additional steady-state demand. On 110–127 VAC input, the 1500 W ceiling reduces the calculated current at 48 V to 31.25 A, and at 60 V to 25 A. State the actual installation voltage in the RFQ, especially when a laboratory prototype will later move to a production facility.

Where This Model Fits

Typical candidates include 24 V industrial controller validation, 48 V DC-DC converter input testing, high-current production fixtures and controlled burn-in. Evaluate startup current, cable drop, capacitive loading and minimum operating voltage alongside continuous demand. A product manager should also identify future test variants: an inexpensive initial selection can become costly if the next DUT exceeds 60 V.

This is a sourcing power supply. For motor controllers, battery-connected equipment or converters that can return energy, the system needs a defined reverse-energy strategy. The bidirectional 2U power supply guide explains a different architecture for sourcing and sinking. TPS can evaluate whether a source, separate load or bidirectional solution better fits the project.

Send TPS a short table of normal, startup and worst-case operating points through the model-specific inquiry page. This allows the technical discussion to resolve power margin and input derating before the commercial quotation is finalized.

Integration checklist covering AC input, USB and Ethernet control, high-current DC wiring and CV remote sensing.

Power distribution, software control and load-end feedback should be reviewed as one system.

Plan Control, High-Current Wiring and Feedback

Choose the Automation Interface Before Purchasing

Built-in USB and Ethernet support remote operation using SCPI or the documented Modbus protocol implementation. The isolated analog interface offers switchable 0–5 V or 0–10 V programming, voltage/current monitoring and status signals. Optional interface modules include industrial network choices such as CANopen, Profinet and EtherCAT; specify the required module explicitly rather than assuming it is included.

For a PLC-controlled fixture, define setpoints, output enable, alarm handling and the behavior after communication loss. For a computer-driven test rack, confirm command support, readback requirements and sequencing with the programming documentation. Remote control signals do not by themselves establish a safety-rated emergency-stop function. TPS can support interface selection and engineering consultation around the complete control architecture.

Engineer the 120 A DC Path

The rear DC connection uses M6 bolts; the manual recommends flexible conductors with ring lugs having 6.5 mm holes. For up to 120 A, it gives 35 mm² / AWG 2 as a reference under specified conditions: cable lengths up to 5 m, ambient up to 30°C and openly suspended insulated conductors. Final sizing must account for installation method, temperature, losses and applicable project rules.

Even a total loop resistance of 5 milliohms produces a calculated 0.6 V drop and 72 W of cable loss at 120 A. That loss affects both delivered power and cabinet temperature. Specify cable length, termination method, strain relief, touch protection and fault protection together. The manual states that the DC output is not internally fused and lacks reverse-polarity protection.

Use Remote Sense With the Actual DUT

CV remote sense can compensate lead drop up to 3 V for this model, within the specified operating limits. It does not remove cable heating or increase the source’s ratings. Follow the manual’s sense-wire routing and polarity instructions, and verify stability with the actual fixture and DUT. The manual cautions that sensing is effective in CV mode and may increase oscillation tendency in other modes.

For higher-current projects, the family supports master-slave and Share Bus parallel operation. TPS should confirm compatible units, current sharing, bus wiring and protection before proposing a parallel system. A reviewed configuration is especially valuable when the production plan requires repeatable cabinets rather than a single laboratory installation.

Rack planning dimensions: 462 mm enclosure depth, at least 559 mm total device depth and 300 mm rear ventilation clearance.

Mechanical dimensions and ventilation clearance are separate requirements; assess both in the actual cabinet layout.

Review Installation, Compliance and Acceptance Evidence

Allow for Depth, Cooling and Facility Power

The enclosure is 462 mm deep, with total device depth of at least 559 mm before project-specific cable allowances. The supplied manual calls for at least 300 mm behind the equipment for ventilation. Use suitable support rails and accommodate the weight, rear terminal covers and cable bend radius. Cooling flows from front to rear through temperature-controlled fans; cabinet doors and exhaust arrangements must preserve that path.

Operating conditions are dry indoor use, 0–50°C, up to 80% noncondensing relative humidity and altitude up to 2000 m. The IP20 chassis is not an outdoor or washdown enclosure. Confirm the temperature at the supply’s intake during full-load operation, including heat from neighboring equipment.

Full-power operation requires the appropriate 208–240 VAC nominal input arrangement, external overcurrent protection and protective earth. Have qualified personnel verify branch-circuit capacity and wiring. The manual specifies direct utility-grid operation, permits transformers and excludes generator or UPS operation. Flag any different power architecture before ordering.

Request Evidence for the Ordered Configuration

The manual identifies IEC/EN/UL 61010-1 and CSA C22.2 No. 61010-1 safety references. It lists Class B emissions references under EN 55011/CISPR 11 and FCC 47 CFR Part 15B, plus EN 61326-1 immunity-related testing. These references support screening; procurement should obtain the applicable declarations, certificates or reports for the exact model and destination.

A supply’s documentation does not certify the complete test rack. Cable routing, grounding, switching equipment and enclosure design remain part of the project review. Adjustable overvoltage, overcurrent and overpower protection, together with overtemperature protection, help manage operating faults. Their settings should be documented against DUT limits during commissioning.

For supplier comparison, request an acceptance plan covering loaded operating points, regulation mode transitions, remote communication, alarm response and thermal operation. Where small signals matter, retain the specified bandwidth when assessing ripple. Do not replace model-specific measurements with a generic claim of precision.

RFQ inputs for TPS: electrical load profile, installation and control requirements, quantity, delivery date and destination.

A complete RFQ connects the electrical requirement with the delivered project scope.

Turn the Selection Into a Complete Project RFQ

TPS serves global B2B customers with relevant power products, equivalent solutions, selection support and integration consultation. Project-specific cable assemblies, rack arrangements and customization can be discussed as part of the delivery scope. Confirm feasibility, responsibilities and acceptance requirements in the quotation.

To request an actionable proposal, provide:

  • Load: DUT type, required voltage/current points, continuous power, startup demand, duty cycle and possible returned energy.
  • Installation: AC voltage/frequency, branch capacity, rack depth, ambient temperature, altitude and cable lengths.
  • Control: PLC or test software, protocol, optional interface, interlocks and data-recording needs.
  • Commercial scope: quantity, shipping address, required delivery date, destination documentation, accessories and integration work.

Ask the quotation to distinguish standard equipment, optional modules, installation accessories and engineering services. Confirm availability, lead time, shipping terms, warranty/RMA arrangements and documentation before issuing a purchase order. No stock level or delivery commitment should be assumed from a product listing.

Discuss Your 60 V High-Current Power Requirement With TPS

Share your operating points, AC service, interface and delivery requirements. TPS can review the EA-PS 10060-120 2U or an equivalent project solution and confirm the quotation scope.

Request a Product Quote or Engineering Consultation

Frequently Asked Questions

Can it deliver 60 V and 120 A simultaneously?

No. That would require 7200 W. At the 3000 W rating, the calculated limit is 50 A at 60 V or 120 A at 25 V. Practical selection should include margin for the load profile.

Can I obtain 3 kW from a 120 VAC outlet?

No. On the 110–127 VAC nominal range, this model is limited to 1500 W. Specify the available AC service so TPS can confirm suitability before quotation.

Can this supply absorb battery or motor regeneration?

It is a sourcing unit, not a regenerative load. Tell TPS about reverse energy so a bidirectional architecture or another protection and loading strategy can be evaluated.

Are industrial fieldbus modules included?

USB, Ethernet and isolated analog control are built in. Industrial network modules are optional. Identify the required protocol and module in the order configuration.

What does TPS need for a project quotation?

Provide the operating envelope, AC service, control interface, installation constraints, quantity, destination and target date. Use the EA-PS 10060-120 2U inquiry route to request selection support, an equivalent solution or an integrated project scope.

EA-PS 9080-50 1U: 1500 W Programmable DC Power for Test Racks,TPS ELECTRIC LLC
Previous
EA-PS 9080-50 1U: 1500 W Programmable DC Power for Test Racks
Read More
EA-PS3000 C Series Power Design Guide: Select and Integrate a DC Test Bench Supply,TPS ELECTRIC LLC
Next
EA-PS3000 C Series Power Design Guide: Select and Integrate a DC Test Bench Supply
Read More

Contact Us

Name *
Company Name *
Email *
Comment *
Get in Touch with TPS
Name *
Business Email *
Company Name
Country/Region
Inquiry Type *
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.