INDUSTRIAL APPLICATIONS | SELECTION & RFQ GUIDE
A production test station needs a DC source that matches the device under test (DUT), protects the fixture, and delivers consistent results across operators. The EA-PS3000 C Series gives engineers a compact programmable DC power supply platform for electronics bring-up, repair, converter validation, and automated test. Its usefulness depends on the actual voltage-current-power envelope, not simply the largest number on the nameplate.
TPS ELECTRIC LLC can support global B2B customers with this product class, project selection, and integrated power solutions. Start with the EA-PS3000 C Series model range; for higher-voltage, lower-current duties, review the EA-PS 3200-02 C configuration. Send TPS your operating points and test requirements to confirm the supply, interface, and integration scope before purchasing.
For printed circuit board assembly (PCBA), sensor modules, and embedded controllers, a variable DC source lets technicians check startup behavior and steady-state consumption before connecting the intended system supply. A 40 V model may suit a 24 V board, but the decision also requires startup current and continuous watts. Set conservative limits for first power-up, then validate normal operation against the board specification.
The practical outcome is a documented bring-up procedure: supply settings, expected current, alarm response, and pass/fail limits. Procurement can then order a defined station configuration rather than an unspecified bench supply.
For a DC/DC converter input stage or another modest-power DUT requiring up to 200 V, the EA-PS 3200-02 C is a candidate when all operating points fit within 160 W. It can support steady input-voltage sweeps with external output measurements. A programmable DC source is not a dielectric withstand tester, and this datasheet does not establish regenerative or battery-simulator operation.
Manufacturing engineers can use a defined supply recipe to power the same assembly repeatedly, check input consumption, and record fixture-level measurements. Burn-in adds thermal and duty-cycle requirements: qualify the installed arrangement under representative loading before releasing it for unattended operation. Panel builders should treat this desktop instrument as test equipment requiring a mounting and wiring plan, rather than assume it is a DIN-rail component.
Choose voltage headroom first, then evaluate current and power at every test point. For nonzero output voltage, the nominal current boundary is the smaller of the model's current rating and its power rating divided by voltage. Transient behavior, sensing compensation, and application margin require separate checks.
For the 160 W, 200 V model, 80 V at 2 A reaches the power ceiling. At 200 V, the calculated limit becomes 0.8 A. A proposed 120 V, 1.5 A test needs 180 W, so it exceeds this configuration. These are calculated selection examples, not measured performance results.
| Model | Power | Voltage | Current |
|---|---|---|---|
| EA-PS 3040-10 C | 160 W | 0-40 V | 0-10 A |
| EA-PS 3080-05 C | 160 W | 0-80 V | 0-5 A |
| EA-PS 3200-02 C | 160 W | 0-200 V | 0-2 A |
| EA-PS 3040-20 C | 320 W | 0-40 V | 0-20 A |
| EA-PS 3080-10 C | 320 W | 0-80 V | 0-10 A |
| EA-PS 3200-04 C | 320 W | 0-200 V | 0-4 A |
| EA-PS 3040-40 C | 640 W | 0-40 V | 0-40 A |
| EA-PS 3080-20 C | 640 W | 0-80 V | 0-20 A |
| EA-PS 3200-10 C | 640 W | 0-200 V | 0-10 A |
For example, a hypothetical 24 V, 8 A load needs 192 W. The 160 W model fails that power requirement even if its current rating looks sufficient; a 320 W configuration warrants evaluation. Ask TPS to compare the available voltage and power variants against your complete load profile, including startup and fault conditions.
The datasheet specifies voltage accuracy below 0.1% of rated voltage and current accuracy below 0.2% of rated current. These are full-rating references, not percentages of each setting. For the 200 V model, the voltage figure corresponds to less than 0.2 V; determine whether that is adequate at your lowest test voltage.
The EA-PS 3200-02 C lists 70 mV peak-to-peak and 13 mV RMS ripple. The measurement bandwidths differ: 20 MHz for peak-to-peak and 300 kHz for RMS. Specify bandwidth, probe method, and measurement location when comparing suppliers. The listed load regulation response below 2 ms for a 10-100% load change does not establish command latency or arbitrary-waveform capability.
Front-accessible DC output and sensing connections simplify bench fixtures. Standard remote sensing regulates voltage at the load connection by compensating cable drop within the supported range. Run sense wiring to the intended regulation point and follow the model manual for connection, compensation limits, and disconnect behavior.
A calculated 2 A flowing through a total power-lead resistance of 0.2 ohm creates a 0.4 V drop and 0.8 W of cable loss. Remote sensing addresses voltage delivery; it does not remove that heat or increase the supply rating. Select conductors, connectors, branch protection, strain relief, and contact ratings for the actual duty.
Configurable overvoltage, overcurrent, and overpower protection shut down the output when their thresholds are reached; overtemperature protection also shuts it down. Distinguish operating current limitation from an overcurrent trip. Coordinate both with legitimate startup demand and the DUT's safe limits, then validate alarm reset and restart behavior.
For capacitive loads, batteries, or motor-driven devices, ask about permitted reverse current, stored-energy discharge, and any required blocking or switching hardware. The supplied document does not establish energy-sinking capability. TPS can review the surrounding fixture and, where the duty requires it, discuss an alternative power platform.
The 160 W and 320 W enclosures measure 308 x 103 x 323 mm; 640 W versions measure 308 x 103 x 350 mm. These are enclosure-only dimensions. Allow additional space for leads, rear interfaces, ventilation, and service access. Use TPS's test rack layout and wiring guide when defining the mechanical scope.
Remote control requires an optional interface card. Specify USB, USB plus Ethernet, or USB plus analog in the purchase configuration. The USB/analog card provides a galvanically isolated 15-pin D-sub interface with selectable 0-5 V or 0-10 V signals for voltage, current, and power settings, plus control and status functions.
The datasheet lists SCPI, ModBus RTU, and LabView support. Confirm the selected card's transport, command documentation, firmware, and software compatibility with TPS before freezing the automated test equipment (ATE) design. Protocol support alone does not demonstrate that every command is available through every transport.
Define the sequence explicitly: establish limits, verify fixture connections, enable output, wait for settling, take measurements, evaluate results, and turn off safely. Test communication loss and controller restart. Use independent instruments when the acceptance limits need traceable DUT measurements beyond the supply's documented accuracy.
For a pilot station, a local PC and USB may be sufficient. Distributed stations may benefit from Ethernet; PLC-controlled fixtures may need the analog option. Compare the complete 200 V bench-source configuration, including its control card and wiring, rather than comparing bare-instrument prices. TPS can support the project selection and discuss custom fixture or rack integration.
The documented AC input is 90-264 VAC at 45-66 Hz with active power factor correction. Operating temperature is 0-50 degrees C, humidity below 80% noncondensing, and cooling uses a temperature-controlled fan. Qualify the temperature around the installed instrument, not only the room thermostat. Request any load-dependent restrictions and maintenance guidance relevant to your duty cycle.
The datasheet identifies protection class I. Provide protective earth and an appropriate mains connection. At higher DC voltages, specify guarded connections, suitable accessories, isolation procedures, and discharge verification. Software output-off is not a substitute for an engineered safe-access arrangement.
The supplied 2018 datasheet does not provide a model-specific certificate package, quantified service-life data, or current availability. Request current documentation, calibration options, warranty terms, and service support for the exact quoted configuration. Do not infer a UL listing, CE declaration, or FCC status from product category or protection features.
IEC 61010-1 addresses safety for measurement, control, and laboratory equipment; citing its scope is not a certification claim for this supply. Agree on applicable requirements for the complete station. TPS can support EMC and safety pre-compliance planning; its EMC-aware test bench guide explains how bench development connects to that work.
Before rollout, define acceptance tests for regulation at the fixture, representative startup, protection response, communications recovery, and thermal operation. For business owners and product managers, these criteria connect the purchase to a usable station and reduce commissioning uncertainty.
TPS can review a standard programmable supply, an equivalent solution, or a broader integration package for global industrial projects. Custom support can cover fixture wiring, mounting, controls, and documentation subject to an agreed scope; changes to the instrument itself require separate feasibility confirmation.
Include the following information so engineering and procurement can evaluate the same configuration:
Ask the quotation to identify the exact model, interface card, included accessories, optional engineering work, documentation, and exclusions. Confirm stock, lead time, shipping terms, and after-sales arrangements in writing. If a substitute is proposed, compare its power envelope, accuracy, noise, control behavior, and installation requirements before approving it.
Request a project-specific selection from TPS. Use the series page to request a model comparison, or submit your operating points through the EA-PS 3200-02 C product page for a focused 200 V, 160 W RFQ. Include the required control card and delivery destination so TPS can confirm the product and solution scope.
No. That point requires 400 W. Its nominal power limit is 160 W, giving a calculated maximum of 0.8 A at 200 V. Check the entire test profile and allow application-specific margin.
Start with the 40 V models, then check current and watts. A 24 V, 8 A load requires 192 W and therefore exceeds a 160 W supply. Send startup and continuous requirements to TPS for confirmation.
No. They are optional card configurations. Specify the required interface and confirm software, protocol transport, and controller compatibility in the RFQ.
No. The supplied datasheet does not establish bidirectional or regenerative operation. Describe reverse-energy conditions to TPS so the correct source, load, or alternative platform can be selected.
TPS offers integrated power and test-system support, including project selection and agreed engineering work. Share the fixture layout, controls, safety requirements, documentation needs, and schedule to define a reviewable proposal.
EA-PUB 10000 4U Series: 30 kW Bidirectional DC Power for Scalable Test Systems
EA-EL 9000 B Series: Programmable DC Loads for Industrial Test Systems
TBM800-53KTIT Industrial Applications: 53 kW Bidirectional Power for Battery Test and Regenerative Aging
YB-D Series Compliance & Testing: Qualify EMI Filters for Industrial Control Panels
EA-PS3000 C Series Power Design Guide: Select and Integrate a DC Test Bench Supply
EA-PS 10060-120 2U: 60 V, 120 A, 3 kW Programmable DC Power Supply
EA-PS 9080-50 1U: 1500 W Programmable DC Power for Test Racks
eTM-605, eTM-605F and eTM-605P Compliance Guide: Qualify 60V Bench Power Supplies for Lab and Production Testing