The EA-PS 10060-120 2U is a programmable DC power supply for teams that need up to 60 V, up to 120 A and a 3 kW sourcing envelope in a 19-inch rack. Its value depends on matching the actual load profile, facility power and integration requirements before purchase.
For system integrators, panel builders, procurement teams and electrical engineers, TPS ELECTRIC LLC supports selection of this product class, equivalent solutions and project integration. Start with the EA-PS 10060-120 2U product and quotation page and use the checks below to define a technically complete request.
Table of Contents
Model limits apply simultaneously; the current available at any voltage also depends on the power limit.
This 60 V programmable DC power supply combines constant-voltage, constant-current and constant-power regulation with adjustable internal-resistance operation. A 5-inch color touchscreen supports local setup, while remote interfaces support automated test equipment. The following values come from the supplied series manual and its model-specific table.
| Selection item | EA-PS 10060-120 2U |
|---|---|
| DC output limits | 0–60 V; 0–120 A; 0–3000 W |
| AC input | 110–127 VAC or 208–240 VAC, each ±10%; 45–65 Hz |
| Low-line DC power | 1500 W on the 110–127 VAC nominal range |
| CV ripple | 10 mV RMS at 300 kHz bandwidth; 100 mV peak-to-peak at 20 MHz bandwidth |
| Load regulation | CV ≤0.05% full scale; CC ≤0.1% full scale |
| Remote sense | Up to 5% of nominal voltage: 3 V for this model, in CV operation |
| Internal-resistance setting | 0.02–24 ohms |
| Built-in control | USB, 100 Mbit Ethernet and isolated 15-pin analog interface |
| Mechanical format | 19-inch, 2U; approximately 12.7 kg / 28 lb |
Full scale is the instrument’s nominal range, rather than the selected operating value. Consequently, regulation figures should not be read as percentages of a small setpoint. Specifications carrying tolerances apply under the manual’s stated conditions, including warm-up and reference temperature. Procurement should confirm the current hardware revision and documentation with TPS.
For a broader voltage or current comparison, the 2U series selection guide provides useful context. Select this particular model when its complete operating envelope covers your device under test, or DUT, with practical margin.
Calculated selection envelope: I ≤ min(120 A, available power ÷ voltage), with voltage limited to 60 V.
A 60 V, 120 A specification does not mean 7200 W is available. With a full-power AC connection, the supply can deliver 120 A up to 25 V; above that point, available current follows the 3 kW power ceiling. These calculated examples illustrate the selection boundary:
| Required operating point | Power | Assessment at full AC input |
|---|---|---|
| 24 V at 100 A | 2400 W | Within nominal limits |
| 25 V at 120 A | 3000 W | At the rated boundary |
| 48 V at 50 A | 2400 W | Within nominal limits |
| 48 V at 62.5 A | 3000 W | At the rated boundary |
| 60 V at 50 A | 3000 W | At the rated boundary |
| 48 V at 100 A | 4800 W | Requires another configuration |
Boundary values leave no allowance for additional steady-state demand. On 110–127 VAC input, the 1500 W ceiling reduces the calculated current at 48 V to 31.25 A, and at 60 V to 25 A. State the actual installation voltage in the RFQ, especially when a laboratory prototype will later move to a production facility.
Typical candidates include 24 V industrial controller validation, 48 V DC-DC converter input testing, high-current production fixtures and controlled burn-in. Evaluate startup current, cable drop, capacitive loading and minimum operating voltage alongside continuous demand. A product manager should also identify future test variants: an inexpensive initial selection can become costly if the next DUT exceeds 60 V.
This is a sourcing power supply. For motor controllers, battery-connected equipment or converters that can return energy, the system needs a defined reverse-energy strategy. The bidirectional 2U power supply guide explains a different architecture for sourcing and sinking. TPS can evaluate whether a source, separate load or bidirectional solution better fits the project.
Send TPS a short table of normal, startup and worst-case operating points through the model-specific inquiry page. This allows the technical discussion to resolve power margin and input derating before the commercial quotation is finalized.
Power distribution, software control and load-end feedback should be reviewed as one system.
Built-in USB and Ethernet support remote operation using SCPI or the documented Modbus protocol implementation. The isolated analog interface offers switchable 0–5 V or 0–10 V programming, voltage/current monitoring and status signals. Optional interface modules include industrial network choices such as CANopen, Profinet and EtherCAT; specify the required module explicitly rather than assuming it is included.
For a PLC-controlled fixture, define setpoints, output enable, alarm handling and the behavior after communication loss. For a computer-driven test rack, confirm command support, readback requirements and sequencing with the programming documentation. Remote control signals do not by themselves establish a safety-rated emergency-stop function. TPS can support interface selection and engineering consultation around the complete control architecture.
The rear DC connection uses M6 bolts; the manual recommends flexible conductors with ring lugs having 6.5 mm holes. For up to 120 A, it gives 35 mm² / AWG 2 as a reference under specified conditions: cable lengths up to 5 m, ambient up to 30°C and openly suspended insulated conductors. Final sizing must account for installation method, temperature, losses and applicable project rules.
Even a total loop resistance of 5 milliohms produces a calculated 0.6 V drop and 72 W of cable loss at 120 A. That loss affects both delivered power and cabinet temperature. Specify cable length, termination method, strain relief, touch protection and fault protection together. The manual states that the DC output is not internally fused and lacks reverse-polarity protection.
CV remote sense can compensate lead drop up to 3 V for this model, within the specified operating limits. It does not remove cable heating or increase the source’s ratings. Follow the manual’s sense-wire routing and polarity instructions, and verify stability with the actual fixture and DUT. The manual cautions that sensing is effective in CV mode and may increase oscillation tendency in other modes.
For higher-current projects, the family supports master-slave and Share Bus parallel operation. TPS should confirm compatible units, current sharing, bus wiring and protection before proposing a parallel system. A reviewed configuration is especially valuable when the production plan requires repeatable cabinets rather than a single laboratory installation.
Mechanical dimensions and ventilation clearance are separate requirements; assess both in the actual cabinet layout.
The enclosure is 462 mm deep, with total device depth of at least 559 mm before project-specific cable allowances. The supplied manual calls for at least 300 mm behind the equipment for ventilation. Use suitable support rails and accommodate the weight, rear terminal covers and cable bend radius. Cooling flows from front to rear through temperature-controlled fans; cabinet doors and exhaust arrangements must preserve that path.
Operating conditions are dry indoor use, 0–50°C, up to 80% noncondensing relative humidity and altitude up to 2000 m. The IP20 chassis is not an outdoor or washdown enclosure. Confirm the temperature at the supply’s intake during full-load operation, including heat from neighboring equipment.
Full-power operation requires the appropriate 208–240 VAC nominal input arrangement, external overcurrent protection and protective earth. Have qualified personnel verify branch-circuit capacity and wiring. The manual specifies direct utility-grid operation, permits transformers and excludes generator or UPS operation. Flag any different power architecture before ordering.
The manual identifies IEC/EN/UL 61010-1 and CSA C22.2 No. 61010-1 safety references. It lists Class B emissions references under EN 55011/CISPR 11 and FCC 47 CFR Part 15B, plus EN 61326-1 immunity-related testing. These references support screening; procurement should obtain the applicable declarations, certificates or reports for the exact model and destination.
A supply’s documentation does not certify the complete test rack. Cable routing, grounding, switching equipment and enclosure design remain part of the project review. Adjustable overvoltage, overcurrent and overpower protection, together with overtemperature protection, help manage operating faults. Their settings should be documented against DUT limits during commissioning.
For supplier comparison, request an acceptance plan covering loaded operating points, regulation mode transitions, remote communication, alarm response and thermal operation. Where small signals matter, retain the specified bandwidth when assessing ripple. Do not replace model-specific measurements with a generic claim of precision.
A complete RFQ connects the electrical requirement with the delivered project scope.
TPS serves global B2B customers with relevant power products, equivalent solutions, selection support and integration consultation. Project-specific cable assemblies, rack arrangements and customization can be discussed as part of the delivery scope. Confirm feasibility, responsibilities and acceptance requirements in the quotation.
To request an actionable proposal, provide:
Ask the quotation to distinguish standard equipment, optional modules, installation accessories and engineering services. Confirm availability, lead time, shipping terms, warranty/RMA arrangements and documentation before issuing a purchase order. No stock level or delivery commitment should be assumed from a product listing.
Discuss Your 60 V High-Current Power Requirement With TPS
Share your operating points, AC service, interface and delivery requirements. TPS can review the EA-PS 10060-120 2U or an equivalent project solution and confirm the quotation scope.
Request a Product Quote or Engineering ConsultationNo. That would require 7200 W. At the 3000 W rating, the calculated limit is 50 A at 60 V or 120 A at 25 V. Practical selection should include margin for the load profile.
No. On the 110–127 VAC nominal range, this model is limited to 1500 W. Specify the available AC service so TPS can confirm suitability before quotation.
It is a sourcing unit, not a regenerative load. Tell TPS about reverse energy so a bidirectional architecture or another protection and loading strategy can be evaluated.
USB, Ethernet and isolated analog control are built in. Industrial network modules are optional. Identify the required protocol and module in the order configuration.
Provide the operating envelope, AC service, control interface, installation constraints, quantity, destination and target date. Use the EA-PS 10060-120 2U inquiry route to request selection support, an equivalent solution or an integrated project scope.
EA-PUB 10000 4U Series: 30 kW Bidirectional DC Power for Scalable Test Systems
EA-EL 9000 B Series: Programmable DC Loads for Industrial Test Systems
TBM800-53KTIT Industrial Applications: 53 kW Bidirectional Power for Battery Test and Regenerative Aging
YB-D Series Compliance & Testing: Qualify EMI Filters for Industrial Control Panels
EA-PS3000 C Series Power Design Guide: Select and Integrate a DC Test Bench Supply
EA-PS 10060-120 2U: 60 V, 120 A, 3 kW Programmable DC Power Supply
EA-PS 9080-50 1U: 1500 W Programmable DC Power for Test Racks
eTM-605, eTM-605F and eTM-605P Compliance Guide: Qualify 60V Bench Power Supplies for Lab and Production Testing