EA-PS 9750-06 1U: 750 V, 1500 W Programmable DC Power Supply for High-Voltage Test Racks

By Lily October 9th, 2026 230 views
The EA-PS 9750-06 1U is a compact 1500W autoranging programmable DC power supply delivering up to 750V and 6A in a 1U rack format. Designed for high-voltage testing, ATE, converter validation, and industrial R&D, it supports USB, Ethernet, SCPI, ModBus RTU, remote sensing, and adjustable protection. TPS provides product selection, integration guidance, and RFQ support for global B2B projects.
EA-PS 9750-06 1U: 750 V, 1500 W Programmable DC Power Supply for High-Voltage Test Racks,TPS ELECTRIC LLC

The EA-PS 9750-06 1U is a programmable high-voltage DC power supply for engineering teams that need up to 750 V in a space-efficient 19-inch rack. Its 1500 W autoranging output, 0-6 A current capability, isolated control interfaces, remote sensing, and built-in protection functions make it a strong candidate for automated test equipment, converter validation, component stress testing, production fixtures, and laboratory power systems.

For a bottom-of-funnel evaluation, however, the headline ratings are only the starting point. System integrators, panel builders, electrical engineers, and procurement teams must confirm the real voltage-current operating points, AC input conditions, rear-panel clearance, high-voltage safety measures, control protocol, documentation package, and delivery requirements. TPS can provide this product or an equivalent solution, help verify the operating envelope, and support integration and project-level RFQs for global B2B customers. To begin a model-specific review, visit the EA-PS 9750-06 1U product page.

What the EA-PS 9750-06 1U Is Designed to Do

This model combines a 0-750 V output range with a maximum 6 A output current and a total power limit of 1500 W. It is housed in a 19-inch, 1U enclosure approximately 500 mm deep and weighs about 10.5 kg. The low rack height is valuable where a test system needs several instruments, switching devices, measurement equipment, safety interlocks, and cooling hardware in one cabinet.

The flexible output stage is the central technical advantage. Instead of offering only one fixed voltage-current point, it can deliver higher voltage at lower current or higher current at lower voltage while remaining inside the 1500 W limit. This lets one supply address multiple test conditions, which may reduce the number of dedicated power sources in an R&D lab or production line.

The unit also supports both local and automated operation. A front-panel graphic display and rotary controls serve setup and bench work, while galvanically isolated USB, Ethernet, and analog interfaces support integration into test software or industrial control architectures. Remote sensing helps compensate for voltage drop between the rear DC terminals and the device under test. A Share Bus supports parallel operation planning with identical units, subject to a proper engineering review.

EA-PS 9750-06 1U RFQ fit overview A central programmable power supply connects to output, rack integration, control, safety, and TPS project support. EA-PS 9750-06 1U 750 V / 6 A / 1500 W Programmable autoranging DC Output envelopeReal V-I load points 1U rack fitDepth and airflow AutomationUSB, LAN, analog TPS supportSelection and RFQ
Figure 1. A useful RFQ evaluates the supply as an output, control, safety, mechanical, and supplier-support package.

Key Specifications for Technical and Commercial Evaluation

The following values are the practical baseline for supplier comparison. They should be confirmed against the current quotation, documentation revision, selected options, and destination-market requirements.

Category EA-PS 9750-06 1U value Why it matters in an RFQ
DC output 0-750 V, 0-6 A, 0-1500 W The required operating points must remain inside all three limits.
AC input 100-264 VAC, 45-65 Hz, active PFC, PF 0.99 Supports broad mains compatibility; input below 150 VAC reduces available output power.
Low-line derating Maximum 1000 W below 150 VAC Critical for 120 VAC installations and mobile or international test equipment.
Efficiency Up to 95% Affects rack heat load, cooling capacity, and operating cost.
Accuracy Voltage <0.1%; current <0.2%; power <1% of rated value Helps define test uncertainty and whether external measurement is required.
Voltage ripple 260 mVpp / 40 mVrms maximum Must be checked against DUT noise sensitivity and acceptance criteria.
Mechanical 19-inch x 1U x approximately 500 mm; approximately 10.5 kg Rear cabling and ventilation may require more depth than the enclosure alone.
Operating environment 0-50 degrees C; <80% RH non-condensing; below 2000 m Enclosure temperature, altitude, and contamination can change system suitability.

How to Interpret the Autoranging Output

The maximum voltage, current, and power ratings are not simultaneous. At full 1500 W power, the theoretical current available at 750 V is approximately 2 A. At 500 V, it is approximately 3 A. The full 6 A rating corresponds to operating points at or below approximately 250 V, subject to the unit's actual output characteristic and other limits. Therefore, an RFQ that only states “750 V and 6 A” would incorrectly imply a 4500 W requirement.

Send TPS a list of actual test points or a voltage-current profile. This lets the sales and engineering team confirm whether the EA-PS 9750-06 1U covers the complete duty cycle, whether parallel capacity is appropriate, or whether a higher-power 750 V platform is a better choice. Teams needing more current can compare the 750 V, 12 A, 3000 W 1U model selection guide.

Simplified 1500 W autoranging selection chart The full 6 A current is available at lower voltages, while current decreases as voltage rises to 750 V because output power is limited to 1500 W. 6 A4 A2 A0 A0 V250 V500 V750 VOutput voltageOutput current 250 V / 6 A500 V / 3 A750 V / approx. 2 A Illustrative power-limit logic Confirm the exact characteristic with TPS.
Figure 2. Simplified selection logic: maximum voltage and maximum current are not available at the same time.

Application Fit and Limits

Where this programmable 750 V DC supply fits well

The model is well aligned with high-voltage, moderate-current test tasks. Examples include DC-DC converter input simulation, inverter and power semiconductor development, capacitor charging research, insulation-related component stressing, high-voltage electronics burn-in, production end-of-line tests, and automated validation stations. The adjustable voltage, current, and power limits allow a test recipe to protect the DUT while reproducing different operating conditions.

Its 1U height is especially useful for multi-channel racks, but buyers should compare total channel power and I/O needs rather than rack height alone. If a project will later require energy to flow back from the DUT, a unidirectional source may not be the right architecture. TPS can assess whether a regenerative or bidirectional platform is more appropriate; the bidirectional power supply selection and US compliance guide provides a useful decision framework.

Conditions that require another solution

This unit is not a fit when the load needs more than 750 V, more than 6 A, more than 1500 W continuously, or more than 1000 W when operated below 150 VAC input. It is also not an electronic load and cannot absorb sustained returned energy like a regenerative sink. Very low ripple requirements may call for additional filtering or a different supply architecture, and safety-critical systems may require project-specific approvals beyond the standards listed in the available datasheet.

These limits do not end the sourcing process. TPS can review an equivalent programmable DC power supply, higher-power platform, bidirectional system, or custom integration package around the actual test requirement. This capability is important when procurement wants a functional alternative rather than a strict model-number substitution.

Rack Integration, Wiring, and Thermal Planning

A 1U front panel does not mean a 1U integration task. The enclosure is approximately 500 mm deep, while the DC output, remote-sense connection, Share Bus, analog interface, USB, Ethernet, input connection, and cooling path are located at the rear or depend on rear access. The rack must provide additional depth for connector bodies, cable bend radius, strain relief, touch protection, and service access.

At up to 750 VDC, panel builders should define conductor insulation ratings, creepage and clearance, protective covers, grounding, disconnect procedures, and clear labeling. Route power conductors separately from sense and communication wiring where practical. Remote-sense leads should be protected and installed so that an open or incorrectly connected sense circuit cannot create an unsafe or uncontrolled condition. TPS can support cable and harness planning; see its guidance on custom cable assemblies and wire harnesses for power electronics.

Temperature-controlled fans reduce unnecessary noise and power use, but the rack still needs an unobstructed airflow path. Use the efficiency figure to estimate heat rather than assuming the supply is thermally negligible. At 1500 W output and 95% efficiency, approximate conversion loss is about 79 W under that illustrative full-load condition. Actual loss depends on input voltage and operating point. Cabinet ambient temperature, neighboring heat sources, inlet temperature, dust, filters, altitude, and maintenance intervals should be part of the design review.

For larger automation systems, coordinate the power supply with AC distribution, branch protection, safety relays, contactors, emergency stop behavior, control wiring, and enclosure ventilation. TPS's resource on industrial control cabinets for automation explains why these interfaces should be specified as one system rather than purchased as unrelated components.

Rack integration planning for a 750 V 1U supply A rack supply requires rear clearance, protected high-voltage cabling, separated control wiring, airflow, and service access. 1U POWER SUPPLY Rear clearance:connectors and bend radius HV wiring:cover, spacing, labeling Signals:sense and control separation Thermal:airflow and service access
Figure 3. Rear-panel access, protected high-voltage wiring, signal routing, and airflow should be defined before the purchase order.

Control, Protection, Compliance, and Reliability

Automation interfaces and repeatable control

The model provides isolated USB and Ethernet interfaces and supports SCPI commands and ModBus RTU. This gives integrators options for scripted test sequences, setpoint changes, monitoring, alarm handling, and production-data capture. The isolated 15-pole analog interface supports switchable 0-5 V or 0-10 V control for voltage, current, and power, plus monitoring and status signals. Before ordering, define which interface is primary, the required update rate, command compatibility, network policy, fault recovery behavior, and software validation responsibility.

Remote sensing can improve voltage accuracy at the DUT by compensating for lead drop, but it does not replace a correctly sized output cable. For parallel operation, confirm whether identical units, Share Bus wiring, protection coordination, and system-level current sharing meet the application. The available datasheet states that parallel operation is possible, but no master-slave function is listed; this distinction should be addressed explicitly in the RFQ.

Protection and high-voltage safety

Adjustable overvoltage, overcurrent, and overpower protection can shut down the DC output and report a status through the display and interfaces. Overtemperature protection adds a thermal shutdown layer. These functions should be mapped to the DUT's safe operating area and the test sequence rather than left at generic defaults.

Because the nominal output exceeds 200 V, the unit includes a discharge circuit. Current TPS product information states that it reduces the output below 60 V within 10 seconds after the DC output is switched off under the specified conditions. This is a valuable risk-reduction feature, but it is not permission to touch the circuit without verification. The finished system still needs an appropriate disconnect, interlock, voltage-presence indication, discharge confirmation, and lockout/tagout procedure based on the end application.

Compliance and document control

The supplied series datasheet lists EN 60950, EN 61326, and EN 55022 Class B. Since standards, product revisions, destination markets, and end-equipment requirements can change, buyers should treat this list as an evaluation starting point. Ask TPS for the current declaration, applicable test reports, manual revision, serial or configuration traceability, and any market-specific documentation needed for the project. Do not infer a certification mark or end-product approval from a general standards list.

Reliability evaluation should also cover operating temperature, humidity, altitude, fan maintenance, expected duty cycle, calibration needs, warranty, spares, and acceptance testing. TPS can coordinate model selection, documentation, integration consultation, equivalent-solution review, and project supply. For programs involving the surrounding hardware, TPS also provides a broader power electronics manufacturing and integration stack.

Control, protection, and documentation checkpoints Four connected stages show test software, isolated interfaces, protection and interlocks, and the final RFQ documentation package. Test controlSCPI / ModBusAnalog setpoints InterfacesUSB / EthernetIsolated analog ProtectionOVP / OCP / OPPOTP / interlocks RFQ packageConfigurationDocuments + terms Define the complete control and safety chain TPS can review the model, integration assumptions, and quote scope.
Figure 4. Reliable automation depends on aligned software, interfaces, protection settings, safety measures, and controlled documentation.

RFQ Checklist for Faster Supplier Confirmation

A complete inquiry enables TPS to move from a generic price request to a technically useful offer. Send the following information:

  • Operating envelope: minimum, nominal, and maximum voltage and current points; continuous power; transients; duty cycle; and load type.
  • Input power: country of use, nominal AC voltage, frequency, branch capacity, and whether the 1000 W low-line limit below 150 VAC is acceptable.
  • Application: DUT type, test objective, source-only or source/sink behavior, sequence duration, and anticipated future expansion.
  • Control: front panel, USB, Ethernet, SCPI, ModBus RTU, 0-5 V, 0-10 V, digital I/O, and required software environment.
  • Performance: accuracy, ripple, response, remote sensing, calibration, data logging, and acceptance-test criteria.
  • Mechanical and thermal: available rack units, usable depth, rear clearance, airflow, ambient temperature, altitude, cable routing, and maintenance access.
  • Safety and compliance: destination market, end-equipment category, current documents required, interlock concept, labeling, grounding, and high-voltage work procedures.
  • Commercial scope: quantity, target delivery date, ship-to country, warranty expectations, approved-equivalent policy, spares, quote validity, and Incoterms if applicable.
  • Integration scope: output cables, sense harnesses, rack assembly, cabinet work, protective devices, test fixture wiring, documentation, or build-to-print services.
EA-PS 9750-06 1U RFQ information checklist Five RFQ inputs lead to model confirmation: load profile, AC input, control, rack and safety, and commercial terms. Build an RFQ that engineering and procurement can approve Load profileV / A / W / duty AC inputMains + derating ControlProtocol + I/O IntegrationRack + safety CommercialQty + delivery TPS model confirmation + quotation
Figure 5. Complete technical and commercial inputs help TPS confirm fit, scope, documentation, and quotation terms faster.

For owners and product managers, the business case is rack density, platform reuse, integration risk, and supplier responsiveness. For engineers, it is the verified operating envelope, control behavior, output quality, and safety architecture. For procurement, it is configuration control, documentation, availability, commercial terms, and confidence that the quoted item will perform in the intended system. TPS brings these viewpoints into one selection and solution-consulting process.

Ready for technical confirmation? Submit your load points, AC mains, rack constraints, interface requirements, quantity, destination, and timeline through the EA-PS 9750-06 1U quote page. TPS can support the specified unit, an equivalent solution, customization and integration consultation, and project supply for global B2B customers.

FAQ

Can the EA-PS 9750-06 1U deliver 750 V and 6 A at the same time?

No. Those are independent maximum ratings and the unit is limited to 1500 W. At 750 V, 1500 W corresponds to approximately 2 A. Provide all required voltage-current points so TPS can confirm that they fit the actual autoranging characteristic.

Will it deliver the full 1500 W from a 120 VAC supply?

No. The published specification states that output power is reduced to a maximum of 1000 W below 150 VAC input. A typical 120 VAC installation must therefore be designed around the lower available output power or use an appropriate higher input voltage.

Can it be integrated into automated test equipment?

Yes. The model provides isolated USB and Ethernet interfaces with SCPI and ModBus RTU support, plus an isolated analog interface. Confirm command compatibility, timing, fault handling, network requirements, and responsibility for test-software validation in the RFQ.

Does the discharge circuit make the 750 V output safe to touch immediately?

No. The discharge circuit helps reduce voltage below 60 V within the specified time after output shutdown, but personnel must verify the actual voltage and follow the finished system's disconnect, interlock, and lockout/tagout procedures before accessing conductors.

What rack space should a panel builder reserve?

Reserve 1U of front-panel height and at least the approximate 500 mm enclosure depth, plus extra rear space for connections, cable bend radius, strain relief, airflow, touch protection, and service access. Check rack load capacity for the approximately 10.5 kg unit.

What can TPS support beyond supplying the model?

TPS can support operating-envelope review, equivalent product evaluation, interface and rack-integration consultation, documentation coordination, cable or cabinet scope, customization discussions, and global B2B project supply. For pricing, availability, and model confirmation, contact TPS through the product RFQ page.

TBM750-53KTIF-S Industrial Applications: 53 kW Bidirectional AC-DC Power for Battery Test and Regenerative Systems,TPS ELECTRIC LLC
Previous
TBM750-53KTIF-S Industrial Applications: 53 kW Bidirectional AC-DC Power for Battery Test and Regenerative Systems
Read More
EA-ELR 10000 2U Regenerative DC Load: RFQ Selection Guide,TPS ELECTRIC LLC
Next
EA-ELR 10000 2U Regenerative DC Load: RFQ Selection Guide
Read More

Contact Us

Name *
Company Name *
Email *
Comment *
Get in Touch with TPS
Name *
Business Email *
Company Name
Country/Region
Inquiry Type *
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.