PRODUCT INTRODUCTION | BIDIRECTIONAL POWER MODULES
The TBM750-53KTIT is a 53 kW isolated, three-phase bidirectional AC-DC power module rated at 750 VDC and 70.7 A. It is a practical candidate for battery pack test equipment, bidirectional power testing, and energy-recycling aging systems that need power to flow between an AC supply and a high-voltage DC bus.
For system integrators, panel builders, electrical engineers, and procurement teams, the purchase decision depends on more than rated kilowatts. AC supply compatibility, the actual DC operating envelope, thermal conditions, controls, qualification documents, and delivery scope determine whether the module fits the project. TPS ELECTRIC LLC provides this product category and supports the engineering discussion needed to move from a module shortlist to an integrated solution.
Review the TBM750-53KTIT and request a project quotation with your AC supply, DC voltage/current profile, and required quantity.
Table of Contents
This module suits a power architecture built around a 750 V-class DC bus and a compatible three-phase AC interface. High-frequency isolation and soft-switching technology are specified, alongside bidirectional operation and automatic parallel operation. These features make it relevant when a test system must supply energy during one operating phase and recover energy during another.
Begin selection with three questions: Does the facility supply fall within the AC limits? Does the required DC operating profile fit the confirmed voltage/current envelope? Can the cabinet and facility accommodate continuous operation and returned power? A rated 750 V value alone does not establish a programmable range or direct compatibility with every battery pack.
The supplied model-specific specification gives the following ratings. Preserve the stated test conditions when comparing suppliers; peak values and nominal ratings are not guaranteed performance at every operating point.
At the rated DC point, 750 V × 70.7 A is approximately 53 kW. This consistency supports an initial rating check, but it does not prove constant-power operation across an unspecified voltage range. Ask for a power-versus-voltage/current envelope and the test conditions used for accuracy and ripple measurements.
| Selection parameter | Specified value or condition |
|---|---|
| Rated power and DC point | 53,000 W; 750 VDC; 70.7 A in either direction |
| AC connection | 3Ph+PE; 380/400/415 VAC nominal; no neutral conductor |
| AC voltage and frequency | 342–460 VAC at full load; 304–342 VAC derating to 80%; 50/60 ±5 Hz adaptive control |
| Maximum AC input current | 94 A maximum |
| DC voltage accuracy and ripple | Accuracy <1%; ripple voltage ≤2%, specified for AC-to-DC operation |
| Peak conversion efficiency | AC-to-DC: 96%; DC-to-AC: 95%, at 400 VAC |
| Power factor and current distortion | PF 0.99; THDi <5%, at 400 VAC, full load, with grid THDu ≤2% |
Figure 1. Rated operating point and AC supply limits from the supplied specification. Scroll horizontally on small screens.
Check the facility supply first. A nominal 480 VAC service exceeds the stated 460 VAC full-load upper limit. Do not assume a direct connection is acceptable. Give TPS the measured supply range and discuss a suitable power interface or an alternative module before approving the design.
The low-line derating statement also matters: a project requiring uninterrupted 53 kW operation cannot assume full output below 342 VAC. Request the detailed derating curve and operating limits for both directions, particularly when supply sag and high cabinet temperature may occur together.
Battery pack testing is a stated application. However, the module should be evaluated as part of the complete power and control architecture. Supply minimum and maximum pack voltage, charge/discharge current, continuous power, transient demands, and the test sequence. TPS can support selection of the power stage and discuss the surrounding cabinet and test-system requirements.
Where the DUT voltage differs from the high-voltage bus, a downstream bidirectional DC-DC stage may be appropriate. The TPS guide to bidirectional DC-DC modules for energy-recycling test systems explains that architectural role. Any pairing still requires confirmation of bus limits, control coordination, and fault behavior.
Energy-recycling power aging can reduce the energy dissipated by a conventional resistive test arrangement. The TBM750-53KTIT supports the AC-DC conversion function required for bidirectional energy transfer. It does not, by itself, establish the performance or safety of a complete aging station.
For an equipment owner assessing operating cost, request an efficiency map across the expected load profile. Peak efficiencies of 96% and 95% describe separate conversion directions. They should not be read as whole-system efficiency or a guaranteed energy-saving percentage. Auxiliary power, downstream conversion losses, duty cycle, and facility power handling affect the business case.
Confirm where recovered energy will go during every test phase. The facility connection, transformer arrangement, and upstream equipment must support the intended reverse power flow. Include the response to AC loss and a blocked return-power path in the system review; grid-connected operation requires site-specific engineering confirmation.
Match the model to the intended bus architecture rather than choosing a similar part number. If your project uses an 800 V-class bus, the TPS overview of an 800 V bidirectional AC-DC platform provides a relevant comparison starting point. Ask TPS to confirm a suitable variant or equivalent solution against your full operating profile; neither interchangeability nor a broader DC range is implied.
Figure 2. Conceptual energy path; downstream equipment and facility integration are project-specific. Scroll horizontally on small screens.
The body measures 435 × 86 × 600 mm without handles, or 489 × 86 × 647.5 mm with handles. Weight is ≤23 kg. Panel builders should reserve space for cable bend radius, terminal access, airflow, removal, and the supporting structure. The 86 mm height alone is insufficient to approve rack fit.
The installation drawing identifies six M4 mounting locations with 5 mm hole depth and warns against screws extending beyond that depth. Use the released drawing to confirm fastening details. Obtain terminal specifications and tightening torques before finalizing conductors, busbars, protective devices, and assembly instructions.
Plan protective earth, isolation, precharge where required, contactors, DC discharge, and emergency-stop behavior at system level. The 94 A maximum AC input rating is a design input, not a standalone breaker recommendation. Qualified engineers must coordinate protection with wiring, installation conditions, and the intended fault response.
CAN and RS485 communication are specified. Request the protocol document, connector pinout, addressing method, termination requirements, command set, status reporting, and behavior after communication loss. The datasheet does not establish a particular application protocol, update rate, or PLC driver.
The system table lists “Expandability: 12,” “Concatenation: 2,” and current-sharing imbalance <5%. Confirm the permitted topology, controller arrangement, isolation constraints, and aggregate operating limits with TPS. These entries should not be converted directly into a guaranteed cabinet rating or assumed series connection without an approved configuration.
Seamless bidirectional switching is described, but no numerical transition-time specification is provided. For sensitive DUTs, include required voltage deviation, settling time, ramp behavior, and source-to-sink transitions in the acceptance plan.
Intelligently controlled forced-air cooling is specified, with front fans and a rear terminal face. Confirm airflow direction and required clearances in the installation manual. Avoid recirculation and use the air temperature at the module inlet when assessing cabinet conditions.
The operating range is −10°C to 45°C at full load; 45°C to 60°C requires derating to 80%. Relative humidity is 5–95%, noncondensing. Below 2,000 m, full-load operation is stated; from 2,000 to 3,000 m, output power decreases by 1% per additional 100 m. Request combined derating guidance for elevated temperature, altitude, and low AC voltage.
For an illustrative thermal estimate, delivering 53 kW DC at 96% efficiency would produce approximately 2.2 kW of conversion loss. This calculation uses the published peak efficiency and is not a worst-case cooling specification. Obtain actual loss and airflow data for the intended load profile before sizing cabinet ventilation.
Figure 3. Mechanical envelope and thermal limits; allow additional wiring and service space. Scroll horizontally on small screens.
The specification says the design complies with IEC 62477-1 and EN 55032, and indicates potential UL, CE, and TÜV qualification. It does not attach certificates, declarations, or test reports. Treat these statements as prompts for document verification rather than proof that every offered configuration carries those approvals.
Ask for evidence matching the exact model and revision: applicable standards and editions, report scope, isolation test results, protective-earth requirements, and any conditions of installation. The complete cabinet may need additional evaluation because cabling, filters, controls, and enclosure construction affect the finished equipment.
For EMC planning, the TPS three-phase EMI filter selection guide provides useful cabinet-design context. A filter must be matched to the actual bidirectional power path, current, voltage, leakage constraints, and test results; fitting a filter alone does not establish compliance.
Reliability review should cover cooling maintenance, fault thresholds, restart behavior, and service access. The specification describes fault protection and temperature-related shutdown, but provides no MTBF value or detailed protection timing. Request those details where they affect uptime commitments or purchase acceptance.
Agree on acceptance tests before ordering: operation at representative source/sink points, communication-loss response, controlled shutdown, and sustained operation under the specified enclosure conditions. Document pass/fail limits and responsibility for measurements. This helps engineering validate suitability while giving procurement a concrete basis for comparing module-only and integrated-system proposals.
TPS can support product selection, engineering consultation, and discussion of custom cabinet or integration requirements for global B2B projects. Specify whether you need a module, a coordinated power subsystem, or a documented cabinet assembly. The agreed scope should identify responsibilities for controls, wiring, functional validation, and final qualification.
Ask TPS to confirm the TBM750-53KTIT against your system requirements. Include these details to make the quotation technically useful:
Procurement should request a written quotation covering the exact model/revision, included accessories, documentation, lead time, warranty, service terms, and shipment scope. Availability, minimum order quantity, pricing, and customization feasibility require current confirmation. For repeat builds, agree on revision control and change notification before releasing the production order.
Figure 4. A complete RFQ connects electrical suitability with integration, qualification, and delivery. Scroll horizontally on small screens.
Move from a module shortlist to a confirmed power solution.
Send your power profile and cabinet requirements to TPS ELECTRIC LLC for model selection, integration discussion, and a project-specific quotation.
Request a TBM750-53KTIT Quote480 VAC is above the specified 460 VAC full-load upper limit. Send TPS your facility supply details to evaluate a suitable interface or alternative product before connection.
No. It is the rated DC voltage. The supplied specification does not define the complete adjustment range. Request the voltage/current envelope for both directions before matching a battery or DC bus.
No. It supplies the AC-DC power conversion function. A complete tester also needs appropriate controls, measurement, DUT interfaces, protection, and confirmed source/sink operating limits.
The supplied specification does not include approval documents. Ask TPS for available evidence covering the exact model, revision, destination market, and proposed configuration.
TPS offers project selection and integration support. Provide your electrical profile, controller requirements, enclosure constraints, quantity, and schedule so TPS can confirm the feasible product and engineering scope.
EA-PUB 10000 4U Series: 30 kW Bidirectional DC Power for Scalable Test Systems
EA-EL 9000 B Series: Programmable DC Loads for Industrial Test Systems
TBM800-53KTIT Industrial Applications: 53 kW Bidirectional Power for Battery Test and Regenerative Aging
YB-D Series Compliance & Testing: Qualify EMI Filters for Industrial Control Panels
EA-PS3000 C Series Power Design Guide: Select and Integrate a DC Test Bench Supply
EA-PS 10060-120 2U: 60 V, 120 A, 3 kW Programmable DC Power Supply
EA-PS 9080-50 1U: 1500 W Programmable DC Power for Test Racks
eTM-605, eTM-605F and eTM-605P Compliance Guide: Qualify 60V Bench Power Supplies for Lab and Production Testing