WELCOME TO OUR BLOG

We're sharing knowledge in the areas which fascinate us the most
click

EA-PU 10000 4U Series: 30 kW Programmable DC Power Units for Scalable Rack Systems

By Lily October 23rd, 2026 128 views
Explore the EA-PU 10000 4U Series—30 kW programmable DC power units with 60–2000 V output, up to 1000 A, autoranging, and scalable master-slave operation. Compare models, AC-input derating, interfaces, cooling, compliance, and rack-integration requirements, then prepare an RFQ-ready specification with TPS.
EA-PU 10000 4U Series: 30 kW Programmable DC Power Units for Scalable Rack Systems,TPS ELECTRIC LLC

The EA-PU 10000 4U Series is a 30 kW, three-phase, programmable DC power-unit platform for high-density source systems. Its ten model classes span 0-60 V through 0-2000 V, with rated current from 40 A to 1000 A depending on the selected voltage class. A flexible autoranging output, CV/CC/CP/CR regulation, active power-factor correction, remote sense, and system buses make the platform relevant to automated test racks, industrial DC buses, component validation, and scalable cabinet-level power systems.

This is a bottom-of-funnel guide for system integrators, panel builders, procurement teams, and electrical engineers. It focuses on the questions that determine whether the platform belongs on an approved vendor list: which model fits the operating envelope, what changes at 208 V AC, how the unit is controlled, what the cabinet must accommodate, and what information TPS needs to produce a useful quotation. For drawings, available configurations, and an RFQ, visit the EA-PU 10000 4U product page.

30-Second Fit Check

  • Good fit: a unidirectional, programmable DC source is required at up to 30 kW per 4U unit.
  • Model range: choose one nominal voltage class from 60 V to 2000 V; available rated-current classes extend from 40 A to 1000 A.
  • AC infrastructure: the input is 208 V to 480 V, +10%/-10%, three-phase, 45-65 Hz. Full 30 kW output requires the higher input range; at 208 V-class input, output is derated to approximately 18 kW.
  • System architecture: the PU is a cost-optimized power unit with LED status indication. Confirm the compatible master/control architecture when full local visualization and coordinated multi-unit operation are required.
  • Not a regenerative load: this is a source-only platform. Projects that must absorb and return energy should evaluate a bidirectional programmable DC solution instead.

What the EA-PU 10000 4U Is - and Why Its Architecture Matters

At its core, the series converts three-phase AC utility power into a regulated DC output. The 19-inch, 4U enclosure provides 30 kW nominal output in a 483 x 177 x 668 mm chassis; minimum overall depth is approximately 802 mm. Standard air-cooled units weigh about 50 kg, while the water-cooled option is about 56 kg. These details make rear support, handling, rack depth, airflow, and service access engineering requirements rather than purchasing footnotes.

The platform uses an autoranging output stage. A traditional rectangular supply may deliver full current only near a narrow operating point. Autoranging lets one selected model supply different voltage/current combinations inside its constant-power envelope. This can reduce the number of source models needed across a test program, but it does not mean maximum voltage and maximum current are available simultaneously. Engineers should submit the complete operating-point list, including transients and dwell time, for confirmation.

EA-PU 10000 4U scalable DC source architecture 3-Phase AC208-480 V Compatible MasterSetpoints + system dataControl interfaces EA-PU 30 kW Unit EA-PU 30 kW Unit Additional Units DC LoadSource operation
System concept: a compatible master coordinates one or more power units; the DC side remains a unidirectional source.

Model Selection by Voltage and Current

Start with the highest required steady-state and transient voltage, then verify current at every operating point against the model's autoranging curve. Do not select by 30 kW alone. Low-voltage applications may demand very high busbar current, while high-voltage applications shift the design burden toward insulation coordination, clearances, connectors, interlocks, and personnel protection.

Model DC Voltage Rated Current Power Efficiency, up to
PU 10060-1000 0-60 V 0-1000 A 30 kW / 18 kW derated 95.1%
PU 10080-1000 0-80 V 0-1000 A 30 kW / 18 kW derated 95.5%
PU 10200-420 0-200 V 0-420 A 30 kW / 18 kW derated 95.3%
PU 10360-240 0-360 V 0-240 A 30 kW / 18 kW derated 95.8%
PU 10500-180 0-500 V 0-180 A 30 kW / 18 kW derated 96.5%
PU 10750-120 0-750 V 0-120 A 30 kW / 18 kW derated 96.5%
PU 10920-125 0-920 V 0-125 A 30 kW / 18 kW derated 96.5%
PU 11000-80 0-1000 V 0-80 A 30 kW / 18 kW derated 95.8%
PU 11500-60 0-1500 V 0-60 A 30 kW / 18 kW derated 96.5%
PU 12000-40 0-2000 V 0-40 A 30 kW / 18 kW derated 96.5%

The 18 kW value applies under the specified 208 V-class AC derating condition. Efficiency is model-dependent and specified at 100% power and 100% output voltage.

Selection rule: send TPS the voltage-current pairs, not only a headline power value. TPS can review the operating envelope, recommend the closest model, and identify when parallel units or a different power architecture would produce a safer or more economical system. Compare the complete lineup on the 30 kW EA-PU 10000 4U series page.
EA-PU voltage and current class selection map Nominal voltage class increases: 60 V to 2000 VRated current 60 V / 1000 A500 V / 180 A2000 V / 40 A Check every operating pointVmax and Imax are not simultaneous
Selection principle: model ratings define an envelope. TPS should confirm the actual duty cycle and operating points before the order is released.

Electrical Performance That Affects the Design

The series provides CV, CC, CP, and CR regulation with fast crossover. Datasheet values include CV load regulation of no more than 0.05% full scale, CV line regulation of no more than 0.01% full scale, and CC load regulation of no more than 0.1% full scale. Voltage measurement accuracy is specified at no more than 0.05% full scale and current at no more than 0.1% full scale. Remote sense can compensate up to 5% of nominal voltage, subject to correct wiring and stability review.

Adjustable overvoltage, overcurrent, and overpower protection cover 0-110% of the respective nominal rating; overtemperature protection shuts down the DC terminal when cooling is insufficient. These are useful safeguards, but they do not replace load-side fusing, emergency-stop logic, contactors, discharge paths, precharge strategy, or application-specific functional safety. At high DC voltage or current, the system integrator must own the complete hazard analysis.

Rack, Cooling, and Power Integration

Forced air moves from front to rear through temperature-controlled fans. The rated output is available up to approximately 40 degrees C; the stated operating range extends from 0 to 50 degrees C. Confirm inlet temperature under worst-case cabinet recirculation, not only the room setpoint. The optional stainless-steel water-cooling configuration can reduce heat released into a dense rack, but the RFQ should define coolant temperature, flow, pressure, water quality, condensation controls, leak detection, and facility connection requirements.

The rear DC connection uses copper rails. At 1000 A, conductor sizing, joint resistance, torque control, busbar bracing, short-circuit protection, and temperature-rise verification are central to reliability. At up to 2000 V DC, insulation coordination and guarded access become equally important. For a packaged solution, TPS can support power-source selection together with industrial control cabinet engineering, custom rack and enclosure work, and project-specific cable assemblies.

EA-PU 10000 4U cabinet integration checklist 4U Power Unit483 x 177 x 668 mm Cool air inlet Hot air exhaust 3-phase protectiondisconnect + conductor plan Rear DC copper railsguarding + torque + support Allow rear service depthand chassis support
A complete quote should account for the rack, cooling path, AC protection, DC conductors, controls, and maintenance access.

Controls, Interfaces, and Automation

Standard galvanically isolated control options include USB, 100 Mbit Ethernet, a front USB host for data acquisition, and a 15-pin analog interface. The analog interface can use 0-5 V or 0-10 V signals for voltage, current, power, and resistance programming, with monitoring and status I/O. Optional communications include CAN, CANopen, RS232, Modbus TCP, Profinet, Profibus, EtherCAT, and additional Ethernet variants. SCPI and Modbus command support plus LabVIEW and IVI drivers help integration teams connect the unit to automated test software.

For parallel systems, the galvanically isolated master-slave bus communicates system data and alarms, while the Share-Bus supports load sharing. Up to 64 units can be coordinated. If every unit is a 30 kW PU, the arithmetic ceiling is 1.92 MW; the actual approved configuration depends on voltage class, master compatibility, cabinet architecture, utility service, protection, and thermal design. Specify the protocol, PLC or test platform, update-rate expectations, cybersecurity constraints, and required software environment in the RFQ.

Application Fit and Boundaries

Typical source-side use cases include supplying inverter and DC/DC converter inputs, energizing industrial DC buses, component burn-in, motor-drive development, battery charging under an external battery-management and safety strategy, and laboratory or production fixtures that require repeatable programmable power. The wide voltage range lets teams select a class for low-voltage/high-current devices or high-voltage power electronics without changing the core automation approach.

Boundary condition: the EA-PU is unidirectional. It cannot absorb reverse energy as an electronic load. If the device under test can regenerate, the system needs a blocking/protection strategy or a source-sink architecture. Use TPS's bidirectional power-supply selection guide to decide whether a regenerative solution is the better fit.

Safety, EMC, and Reliability Review

The datasheet lists EN/IEC/UL 61010-1, CSA C22.2 No. 61010-1, and BS EN 61010-1 safety references. EMC references include EN 55011 Class B, CISPR 11 Class B, FCC 47 CFR Part 15B Class B, and EN 61326-1 with specified immunity tests. The enclosure is appliance Class I and IP20, with pollution degree 2, operation up to 2000 m altitude, and non-condensing humidity up to 80%.

Procurement should not treat a standard listed in a datasheet as automatic proof that every project, configuration, or final cabinet is certified for every destination. Ask TPS for the current declaration, report, mark, or certificate relevant to the exact product code, cooling option, interface, shipment country, and end-system use. System-level wiring, enclosures, switching devices, and safety functions can change the compliance scope.

Three-layer compliance review for an EA-PU power system Product referencesSafety + EMC standardslisted in datasheet Exact configurationModel + cooling + interfacecurrent evidence required Final systemCabinet + wiring + safetyseparate assessment scope
Compliance review should move from product references to exact configured-unit evidence and then to the completed system.

Supplier and Procurement Checklist

A technically complete offer should identify the exact PU model and product code, AC-input condition, air or water cooling, required interface module, compatible master/control unit, parallel-system accessories, DC connection hardware, documentation package, and commissioning scope. It should also state lead time, warranty, Incoterms, destination, and any acceptance testing. If local control from a color display is mandatory, say so; the PU architecture is optimized around LED status and remote/master control.

TPS ELECTRIC LLC can support global B2B customers with product selection, equivalent-solution review, rack and cabinet integration, control-interface planning, custom wiring, and project-level engineering consultation. Teams comparing a fully featured stand-alone source with a cost-optimized power-unit architecture can also review the 30 kW programmable DC power-supply selection guide.

RFQ workflow for the EA-PU 10000 4U Series 1. Operatingpoints + dutyV, A, kW, time 2. AC utility+ environment208-480 V, cooling 3. Control+ safetyprotocol, interlocks 4. TPS review+ confirmationmodel, options, system RFQ-readyquotation
Better RFQ inputs let TPS confirm the model, options, system boundaries, and commercial scope with fewer clarification cycles.

Build an RFQ TPS Can Act On

For a fast technical review, send the following:

  • minimum, nominal, and maximum DC voltage;
  • current required at each voltage, continuous power, peak power, peak duration, and duty cycle;
  • whether the load can return energy to the source;
  • available three-phase voltage, frequency, site power limit, and destination country;
  • ambient temperature, altitude, enclosure, airflow, and preferred cooling method;
  • single-unit or parallel-system target, compatible master requirements, and future expansion;
  • control protocol, analog I/O, data logging, software/driver, and response-time needs;
  • DC cable or busbar length, remote-sense requirement, load capacitance, and protection concept;
  • required standards evidence, acceptance tests, documentation, quantity, and delivery schedule.

Confirm the Right 30 kW Power-Unit Configuration

Send TPS your operating points and integration constraints. Our team can help confirm the voltage/current class, 208 V derating impact, control architecture, cooling option, parallel-unit plan, and project deliverables before quotation.

View the EA-PU 10000 4U Series and Request a Quote

Frequently Asked Questions

Does every EA-PU 10000 4U model deliver 30 kW?

Each listed model has a nominal 30 kW power rating, but available power depends on AC input and the selected voltage-current operating point. Under the specified 208 V-class input condition, output is derated to approximately 18 kW. Ask TPS to validate your complete duty profile.

Can the EA-PU 10000 4U operate as a stand-alone bench supply?

It is a cost-optimized power unit with LED status indication and remote/master-oriented control. Do not assume the local user experience of a full display-equipped supply. Define the intended master, interface, and local-control requirements in the RFQ so TPS can confirm the correct architecture.

How many units can be connected in parallel?

The master-slave and Share-Bus architecture supports up to 64 coordinated units. Sixty-four 30 kW units equal a theoretical 1.92 MW, but an approved installation depends on a common compatible voltage class, master selection, AC infrastructure, busbars, protection, cooling, and cabinet engineering.

Can the series sink current or regenerate power to the grid?

No. The EA-PU 10000 4U is a unidirectional DC source. If the device under test returns energy, specify the regenerative behavior and fault cases so TPS can propose a bidirectional source-sink system or an appropriate protection approach.

What is the minimum information needed for a quotation?

Provide voltage-current operating points, power and duty cycle, AC service, cooling and ambient conditions, control protocol, single/parallel architecture, destination, compliance documentation, quantity, and requested delivery date. Those inputs allow TPS to quote a defined configuration instead of an incomplete base unit.

ONV-H3108PF Industrial Applications: 8-Port Gigabit PoE with Dual SFP for CCTV, Wi-Fi, and Edge Networks,TPS ELECTRIC LLC
Previous
ONV-H3108PF Industrial Applications: 8-Port Gigabit PoE with Dual SFP for CCTV, Wi-Fi, and Edge Networks
Read More
ONV-H3016PFD-250 19-Port Gigabit PoE Switch: RFQ-Ready Selection and Integration Guide,TPS ELECTRIC LLC
Next
ONV-H3016PFD-250 19-Port Gigabit PoE Switch: RFQ-Ready Selection and Integration Guide
Read More

Contact Us

Name *
Company Name *
Email *
Comment *
Get in Touch with TPS
Name *
Business Email *
Company Name
Country/Region
Inquiry Type *
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.