A 24 V board that resets during startup can turn a simple bench-supply purchase into a fixture redesign. Selecting the right source requires checking current headroom, cable losses, control behavior, and test repeatability before approving the purchase order.
The eTM305F and eTM305P, listed by TPS as eTM-305F and eTM-305P, both provide adjustable 0–30 V, 0–5 A output with a 150 W rating. This guide helps engineers, system integrators, panel builders, and procurement teams turn those specifications into a test-station decision. TPS ELECTRIC LLC offers these products and supports project selection, integration consultation, and global B2B sourcing.
Evaluate the eTM-305F for manual bench work or review the eTM-305P for programmable testing with your actual load profile.
Choose the F model when an operator sets a stable voltage and current limit. Choose the P model when recurring recipes, programmed steps, or remote setpoints are part of the acceptance procedure. An optional communication connector alone does not make the F model programmable.
| Selection factor | eTM-305F | eTM-305P |
|---|---|---|
| Output rating | 0–30 V, 0–5 A, 150 W | 0–30 V, 0–5 A, 150 W |
| Display / setting resolution | 4-digit; 10 mV / 10 mA | 4-digit; 10 mV / 1 mA* |
| Setting accuracy | Voltage: ≤0.1% + 5 digits; current: ≤0.2% + 10 digits | Voltage: ≤0.1% + 5 digits; current: ≤0.2% + 10 digits |
| Ripple | Voltage: ≤10 mVrms; current: ≤10 mArms | Voltage: ≤10 mVrms; current: ≤10 mArms |
| Workflow | Voltage/current presets, power display, output ON/OFF | Hardware List sequence output; six quick parameter memories |
| Optional rear communication | RS485 / RS232 / USB; output switching and reading only | RS485 / RS232 / USB; setting and programming supported |
| Protection information | Confirm the required protection functions with TPS | Catalog lists overvoltage, overcurrent, overpower, overtemperature, and short-circuit protection |
| Bare-unit dimensions | 280 D × 130 W × 165 H mm | 280 D × 130 W × 165 H mm |
Use this table to shortlist a configuration, then confirm the interface option and model-specific documentation. It does not establish readback accuracy, calibration traceability, or the availability of every connector on one unit.
Calculate power as voltage multiplied by current, but treat the 30 V and 5 A limits as separate constraints. A 24 V board drawing 4 A needs 96 W and fits the catalog envelope. A 12 V assembly drawing 6 A needs only 72 W but exceeds the current rating. A 30 V, 5 A test reaches 150 W and leaves no nameplate margin.
Record normal load, startup peak, peak duration, and duty cycle. For example, a board operating at 24 V and 3 A may briefly demand more than 5 A while charging input capacitors. A current-limited startup can then cause resets even though steady-state consumption is acceptable. Confirm the transient behavior with a representative DUT rather than assuming undocumented overload capability.
Include lead losses in the voltage budget. With an illustrative 0.10-ohm total loop resistance at 4 A, cable drop is 0.4 V and cable dissipation is 1.6 W. A 24.0 V source setting would deliver approximately 23.6 V at the DUT. Raising the setpoint is appropriate only after checking the DUT maximum voltage, changing loads, and no-load conditions.
If the current requirement exceeds 5 A, ask TPS to compare another output class using the eTM3010 30 V, 10 A selection guide. Do not assume parallel operation is supported.
A 1 mA setting increment does not establish 1 mA accuracy. The catalog expresses setting accuracy using a percentage plus digits but does not fully define the percentage reference or measurement conditions. Request clarification before converting that expression into an absolute tolerance.
Likewise, the stated RMS ripple does not specify peak-to-peak noise, switching spikes, or test bandwidth. For noise-sensitive analog boards, define your measurement method and allowable DUT-terminal disturbance. Use external calibrated instruments where pass/fail limits require evidence beyond the front-panel indication.
The eTM-305F bench supply suits troubleshooting, repair, and supervised functional checks with manually preset limits. Its optional rear communication can support output switching and reading; the catalog explicitly excludes remote setting and programming. A fixture that must change voltage automatically needs a different control plan.
The eTM-305P programmable supply adds hardware List sequence output, six quick parameter memories, and remote setting/programming through an ordered interface option. These functions suit repeated test recipes, voltage-window checks, and stations shared across products or shifts.
Consider an illustrative 24 V controller test at 20 V, 24 V, and 28 V, provided those values fall within the controller's approved operating window. Define the current limit, dwell time, required settling, and measurements at each step. A programmed sequence can standardize the stimulus, but it does not automatically acquire all DUT data or determine pass/fail.
The catalog does not state List depth, minimum dwell time, trigger options, command latency, or a specific software protocol. Provide TPS with your proposed recipe and controller environment before writing the automation specification. Request the command manual and confirm interface hardware, drivers, addressing, and communication-loss behavior. Avoid assuming SCPI, Ethernet, or a native PLC protocol.
For procurement, compare total station cost: operator setup time, script development, validation, cables, training, and maintenance. A manual supply can be practical for occasional investigation; a recurring voltage sweep creates a stronger case for the P model. Evaluate the workflow on a pilot station before duplicating it.
Panel builders can use either unit to validate control boards before installation. These desktop instruments are not documented DIN-rail replacements or automatically suitable for unattended cabinet service. System integrators should include the fixture, measurement equipment, and safe shutdown method in the station specification.
TPS can help align the source and supporting integration scope. The build-versus-partner guide for power test systems offers a useful framework when several identical stations must be deployed.
Use short leads with conductor size, insulation, connectors, and fixture contacts rated for the operating conditions. Include relay contacts and adapters in the resistance budget. Measure voltage directly at the DUT under maximum expected load. Remote sensing is not established by the supplied catalog, so design the fixture without assuming automatic lead-drop compensation.
Set voltage and current limits before enabling output. During normal constant-voltage operation, the source holds the set voltage within its operating limits. When the load reaches the current limit, constant-current operation reduces voltage. That behavior can help during board bring-up, but it does not replace a complete protection assessment.
The P series lists five protection functions. Confirm thresholds, response, latch/reset behavior, and interaction between current limiting and overcurrent protection. A listed short-circuit function does not demonstrate that every connected board survives every fault. Sensitive DUTs may require additional fixture protection based on stored energy and allowable fault exposure.
Check how output negative, chassis earth, and the measurement system should be connected. The catalog shows a ground terminal but does not establish output-to-earth isolation limits. Obtain those limits before connecting grounded oscilloscopes, multiple supplies, or shared fixture returns. Battery and regenerative loads also require a reverse-energy review; neither model is documented here as a sinking or regenerative source.
Reserve space beyond the 280 × 130 × 165 mm chassis for leads, rear connectors, operator access, and ventilation. The rear fan needs an unobstructed airflow path. Maximum operating ambient, clearance, acoustic performance, and thermal derating are not supplied; request these for long runs or enclosed fixtures.
The catalog shows an optional 110/220 V selector arrangement. Specify destination mains, plug, cord, and the exact input configuration in the RFQ. Follow the approved manual when setting any selector. Do not assume universal autoranging input from the existence of an input socket.
For an enclosed station, apply the broader airflow planning principles for control cabinets, while obtaining the instrument's own installation limits.
Request safety and EMC documentation identifying the exact quoted model and applicable configuration. The supplied catalog does not establish UL, ETL, CE, or other certification status. A general supplier certificate or a mark on a related product does not resolve a model-specific purchasing requirement.
Define acceptance checks around real operation: voltage/current setting verification, DUT-terminal voltage under load, startup behavior, ripple measurement conditions, communication commands, and a representative extended run. Agree on the method, tolerances, and records before ordering the pilot unit. Discuss calibration documentation if test results require traceability.
TPS offers these products alongside power integration and engineering consultation for global B2B customers. Ask TPS to review fixture integration, configuration changes, or an equivalent source when a requirement falls outside the catalog. Customization scope and feasibility should be agreed for the project.
Commercial approval should also establish quoted configuration, lead time, accessories, warranty/service terms, and support responsibilities. Confirm availability and delivery milestones rather than treating this guide as a stock commitment.
An effective RFQ connects electrical requirements with the intended test procedure. Include the following information in one inquiry so TPS can assess the source and integration scope together:
Ask for confirmation of the P model's current setting resolution, included interface accessories, and the final model/configuration on the quotation. This gives procurement a clear basis for comparing bids and engineers a stable basis for approving the station.
Ready to approve a 30 V, 5 A test source?
Request an eTM-305F quotation for manual test stations or an eTM-305P quotation for programmed sequences. Send TPS your DUT profile and acceptance criteria for product selection, integration consultation, or an equivalent solution proposal.
No. Although the catalog groups them with a broader enclosure family, both 30 V, 5 A models are listed at 150 W. Select by the individual model rating rather than the family heading.
The supplied catalog limits F-series rear communication to output switching and reading. For remote voltage/current setting and programming, evaluate the P model and specify its required communication option.
The supplied catalog states 1 mA below 10 A, while the online listing differs. Request written confirmation for the ordered eTM-305P. Setting resolution is separate from accuracy and readback performance.
Neither function is established by the supplied documentation. Share reverse-current and discharge requirements with TPS to assess protection and an appropriate bidirectional or source/load solution.
Send the DUT voltage/current profile, manual or programmed workflow, interface requirement, quantities, destination, and target date. Include mandatory documentation and acceptance limits so TPS can confirm configuration, project fit, and delivery terms.
EA-PUB 10000 4U Series: 30 kW Bidirectional DC Power for Scalable Test Systems
EA-EL 9000 B Series: Programmable DC Loads for Industrial Test Systems
TBM800-53KTIT Industrial Applications: 53 kW Bidirectional Power for Battery Test and Regenerative Aging
YB-D Series Compliance & Testing: Qualify EMI Filters for Industrial Control Panels
EA-PS3000 C Series Power Design Guide: Select and Integrate a DC Test Bench Supply
EA-PS 10060-120 2U: 60 V, 120 A, 3 kW Programmable DC Power Supply
EA-PS 9080-50 1U: 1500 W Programmable DC Power for Test Racks
eTM-605, eTM-605F and eTM-605P Compliance Guide: Qualify 60V Bench Power Supplies for Lab and Production Testing