K19H-UP1000S AC-DC Power Supplies: 12–48 V Selection and RFQ Guide

By Lily November 2nd, 2026 118 views
Explore the K19H-UP1000S industrial AC-DC power supply series with 12V, 24V, 28V, 36V, and 48V outputs, 900–1008W ratings, and active PFC. Compare current capacity, cooling requirements, protection features, and installation considerations to select the right model. TPS ELECTRIC LLC supports product selection, integration consultation, and project-specific RFQs.
K19H-UP1000S AC-DC Power Supplies: 12–48 V Selection and RFQ Guide,TPS ELECTRIC LLC

Choosing a 1 kW-class industrial AC-DC power supply starts with the actual load, cooling arrangement, and installation constraints. The K19H-UP1000S series gives equipment teams five fixed-output options from 12 V to 48 V in a compact chassis. TPS ELECTRIC LLC offers these products and supports B2B customers worldwide with selection, engineering consultation, and integration discussions.

For system integrators, panel builders, electrical engineers, and procurement teams, the key distinction is simple: the 12 V model delivers 900 W, while the 24 V, 28 V, 36 V, and 48 V models are rated at 1008 W. Neither rating should be treated as unconditional output in every enclosure. This guide turns the specification into a practical shortlist and an RFQ that TPS can evaluate against your project.

Compare the Five K19H-UP1000S Output Models

Select the nominal rail first, then verify continuous current and the allowed load envelope. The series includes active power factor correction (PFC), a 90-264 VAC input range, and a listed efficiency of 93% at 230 VAC. The following values come from the supplied product specification; model links lead directly to TPS quotation pages.

TPS model / product page Output Rated current Rated power Ripple and noise
K19H-UP1000S12 12 VDC 75 A 900 W 200 mVp-p
K19H-UP1000S24 24 VDC 42 A 1008 W 300 mVp-p
K19H-UP1000S28 28 VDC 36 A 1008 W 300 mVp-p
K19H-UP1000S36 36 VDC 28 A 1008 W 360 mVp-p
K19H-UP1000S48 48 VDC 21 A 1008 W 480 mVp-p

A useful comparison must include voltage tolerance, current, ripple, mechanical fit, and recovery behavior. A lower purchase price does not compensate for an unsuitable DC rail or a cabinet that cannot remove the heat. Ask TPS to review these constraints together before approving the production bill of materials.

Five K19H-UP1000S models compared by DC voltage, rated current, and power.

Figure 1. The 12 V version is 900 W; the other four versions are 1008 W under the specified operating conditions.

Match the Voltage to the Equipment

The 12 V / 75 A option is a candidate for high-current equipment rails and fixed-voltage test fixtures. At 75 A, cable resistance and termination quality become major design inputs. The 24 V / 42 A model suits evaluation for automation equipment and centralized DC distribution where every connected load accepts the selected voltage.

Choose the 28 V / 36 A version when the equipment specifically requires a 28 V rail. The 36 V / 28 A supply is another option for compatible actuators or embedded equipment. The 48 V / 21 A model can serve compatible 48 V subsystems with lower current than a lower-voltage rail at equal power. These are application candidates, not approvals for every load.

Evaluate the Electrical Operating Envelope

All five models list ±5% output adjustment, ±1% output accuracy, and ±0.5% line and load regulation. Trim is for setting a rail within the allowed range; it does not establish programmable operation or additional power capacity. Confirm the permissible current when using an adjusted voltage. The specification does not establish remote sensing, digital control, or parallel current sharing.

Build a Load Budget With Startup Margin

As an engineering example, a 24 V load drawing 30 A continuously requires 720 W. That is below the 1008 W nameplate, but the available margin changes with input voltage and cooling. Document startup duration, simultaneous loads, capacitive charging, and transient current. The 105-150% overload protection band is not a guaranteed peak-power allowance.

Use the specified ripple limits against the load requirement. The datasheet measures ripple with a 30 cm twisted connection, 0.1 µF and 47 µF capacitors at the load, and a 20 MHz oscilloscope bandwidth. A different harness or measurement arrangement may give different results. Sensitive circuitry may need local regulation or filtering, confirmed by equipment testing.

Check the Mains Connection and Power Interruptions

Rated input is 100-240 VAC at 50-60 Hz; the operating range is 90-264 VAC. Listed input current is 5 A at 230 VAC and 11 A at 110 VAC, with a 60 A cold-start inrush at 230 VAC. Coordinate upstream protection using the actual installation and approved data. Power factor is listed above 0.98 at 100 V and above 0.95 at 230 V.

Setup/rise/hold-up times are 500/30/5 ms at 115 VAC and 300/30/10 ms at 230 VAC. If a controller must ride through longer interruptions, evaluate a separate backup architecture. A wide input range alone does not provide uninterrupted output.

Electrical selection checklist covering load, DC distribution, mains input, and acceptance testing.

Figure 2. Check usable output and system behavior before treating the wattage rating as a purchasing decision.

Confirm Cooling and Installation Before Release

Read the Fan and Fanless Load Curves

The specification distinguishes operation with and without a fan. Its thermal curve indicates approximately 100% load with fan cooling up to 50°C, followed by derating toward 60°C. Without a fan, the curve shows about an 80% load baseline, with further derating above roughly 40°C. These are approximate graph readings; obtain confirmed limits for your installation.

The input-voltage curve also matters: with a fan, the plotted load rises from approximately 80% at 90 VAC to 100% around 115 VAC. Fanless operation is shown near 80% across the illustrated input range, subject to thermal restrictions. Do not multiply separate curve values or assume which limit governs without clarification. Ask TPS to confirm the combined operating envelope and required airflow.

The working temperature range is -20°C to 60°C, with 10-90% RH and no condensation. This range does not mean full output throughout. For the 24 V example, an 80% allowance corresponds to 806.4 W before any further applicable restrictions. A 720 W load could therefore have much less reserve than the nameplate comparison suggests.

Check Mounting, Terminal Access, and Wiring

Overall dimensions are 214 × 82 × 48 mm, with a listed weight of 1.2 kg. Use the dimensional drawing to approve the mounting pattern. When mounting from the bottom, screw penetration into the supply must not exceed 4 mm. Account for plate thickness, screw length, and service access before releasing fabrication drawings.

The input terminal is identified as 3P-8.25. The 12 V, 24 V, and 28 V models use 2P M5 copper screw output terminals; the 36 V and 48 V models use 4P (8.25) terminals. Confirm the exact pin assignment, allowable conductors, and tightening torque. Terminal descriptions alone do not define the approved wiring arrangement.

Plan protective-earth bonding, branch protection, strain relief, touch protection, and cable routing around the exposed assembly. The supplied specification gives no enclosure ingress-protection rating. TPS can discuss custom cable and harness support and enclosure integration for the complete equipment.

Fan-assisted versus fanless cooling considerations, chassis dimensions, and maximum bottom screw penetration.

Figure 3. Approximate load-curve readings guide the initial review; confirm airflow and combined derating with TPS.

Review Protection, Standards, and Reliability

Make Fault Recovery Part of the Equipment Design

Overload protection is specified at 105-150% with hiccup operation and automatic recovery. Output short circuit uses lock protection, requiring power to be turned off for five minutes before restoration. Overvoltage protection is listed at 120-140% of output voltage with the same power-off reset requirement. Plan the service procedure and restart sequence accordingly.

Brownout protection is listed at 70 VAC with automatic recovery. Overtemperature protection shuts down output when shell temperature exceeds 115°C and restores automatically. That shutdown threshold is not a permitted design temperature. Equipment-level controls should address unwanted restart, fault indication, and loss of DC power according to the application.

Distinguish Listed Standards From Verified Approvals

The datasheet lists GB4943, EN60950-1, and EN62368-1 under safety, and GB/T9254-2008, GB17625.1-2012, EN55032 Class B, and EN61000-3-2 under EMC. These references support a documentation review; they do not establish a current third-party certificate, UL listing, or approval of the finished cabinet. Request model-specific reports and the applicable editions for the destination market.

Listed withstand voltage is 3 kVAC input-to-output, 1.8 kVAC input-to-frame ground, and 0.6 kVAC output-to-frame ground for one minute. Leakage current is below 0.75 mA at 240 V. Verify how these values fit the equipment safety architecture. EMC behavior must also be assessed with the intended enclosure, grounding, wiring, and connected loads.

Use Reliability Data Within Its Stated Conditions

MTBF is stated as greater than 50,000 hours using MIL-HDBK-217F at 25°C. It is a calculated reliability indicator, not a warranty or guaranteed service life. The datasheet generally references measurements at 230 VAC, rated load, 25°C ambient, and 70% humidity unless otherwise specified. Procurement should retain the approved specification and acceptance requirements with the purchase order.

Overload, short-circuit, overvoltage, brownout, and overtemperature recovery requirements.

Figure 4. Automatic recovery and power-off reset are different behaviors; verify that both fit your operating procedure.

Define TPS Project Support and Your RFQ

TPS can supply the K19H-UP1000S models and help assess related products or an equivalent solution when a project needs a different interface, operating envelope, or architecture. Selection support can extend to engineering consultation and project-level integration. Product customization and special configurations require a feasibility review rather than an assumption that every feature is available.

For a complete build, TPS provides related power-electronics manufacturing services and industrial control cabinet solutions. Discuss the scope as a coordinated package: power supply, mechanical enclosure, harnesses, assembly, and agreed verification. This gives project managers and procurement a clearer basis for comparing component-only and integrated quotations.

Send the Information That Changes the Quotation

  • Electrical: model or required voltage, continuous and peak current, startup duration, AC mains, and allowable ripple.
  • Integration: enclosure drawing, ambient conditions, airflow, wiring length, terminal requirements, and mounting constraints.
  • Verification: destination market, required certificates or reports, sample tests, and acceptance criteria.
  • Commercial: prototype quantity, production forecast, target delivery date, and shipping destination with postal code.

Ask TPS to confirm availability, lead time, MOQ, warranty terms, documentation, and quotation validity. These commercial details are not specified in the supplied datasheet. For recurring production, also discuss revision control, approved samples, and change notification. Attach a load profile and drawing so the response can address technical fit as well as price.

Request a Model-Specific Quote From TPS

Start with the rail your equipment requires: 12 V high-current supply, 24 V automation supply, 28 V equipment supply, 36 V DC supply, or 48 V industrial supply. On the selected product page, use the quotation inquiry and include your project requirements. TPS can then review the model, integration scope, and delivery assumptions together.

RFQ checklist for electrical, integration, verification, and commercial requirements.

Figure 5. A complete RFQ helps TPS confirm the product and project scope before procurement commits.

Frequently Asked Questions

Is every K19H-UP1000S model rated at 1000 W?

No. The 12 V / 75 A version is rated at 900 W. The 24 V, 28 V, 36 V, and 48 V versions are each rated at 1008 W. Available output also depends on input and cooling conditions.

Can I use it at full power without a fan?

The supplied curves do not support unconditional full-power fanless use. They show approximately 80% load without a fan and further thermal derating at higher temperatures. Confirm airflow and allowable load for your enclosure with TPS.

Does it restart automatically after a short circuit?

The specification describes a latched short-circuit shutdown requiring power off for five minutes before restoration. Overvoltage uses the same reset approach. Overload, brownout, and overtemperature have different specified recovery behaviors.

Can I connect units in parallel or use remote control?

Parallel current sharing, remote sensing, and digital control are not established by the supplied specification. Include these needs in the RFQ so TPS can evaluate a suitable configuration or another power solution.

What should procurement request before ordering?

Request the approved model specification, required safety and EMC evidence, confirmed operating limits, and agreed acceptance criteria. Also obtain pricing, availability, lead time, MOQ, warranty terms, and shipment details for the actual quantity and destination.

YB-B Series IEC Inlet EMI Filter: RFQ-Ready Power Entry Modules for Compact Equipment,TPS ELECTRIC LLC
Previous
YB-B Series IEC Inlet EMI Filter: RFQ-Ready Power Entry Modules for Compact Equipment
Read More
eTM305F vs eTM305P: Design a 30V 5A Bench Supply Setup for Repeatable PCB Testing,TPS ELECTRIC LLC
Next
eTM305F vs eTM305P: Design a 30V 5A Bench Supply Setup for Repeatable PCB Testing
Read More

Contact Us

Name *
Company Name *
Email *
Comment *
Get in Touch with TPS
Name *
Business Email *
Company Name
Country/Region
Inquiry Type *
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.